Bracket for attaching the Kowa fundus camera to the Haag-Streit 900 slit lamp.

نویسندگان

  • D H Brennan
  • T J Price
  • J A Turnbull
چکیده

A bracket has been designed to allow a Kowa RC II fundus camera to be mounted firmly on a Haag-Streit goo slit lamp. The bracket provides a steady support which is of particular importance in fluorescein fundus angiography. The bracket consists oftwo parts. The upper part of mild steel and finished in satin chrome fits into the camera shoe and can be locked into place. The lower part is black anodised aluminium alloy and replaces the tonometer guide plate. The halves of the bracket mate together and permit rotation and locking by means of a friction clamp (Figs I and 2). A further modification enables the bracket to be attached to a Nikon slit lamp.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Depth measurement with the slit-lamp microscope.

The sagittal distance of ocular structures can be obtained with a slit-lamp microscope providing the movement of the slit-lamp can be measured. A simple device consisting of a pointer attached by a spring clip to the axle of a Haag-Streit 900 slit-lamp is described. The pointer rides over a scale which slides with the slit-lamp. Comparisons of anterior chamber depth and lens thickness showed a ...

متن کامل

Slit-lamp photography made easy by a spot metering system.

The use of a standard 35 mm camera with a spot metering system to take slit-lamp photographs is described. This system is mounted on a standard Haag-Streit slit-lamp and can be used with good results even by inexperienced operators.

متن کامل

A new method of estimating the depth of the anterior chamber.

A new method of estimating the depth of the anterior chamber with an accuracy of approximately 0-1 mm is described. The estimate is made with a conventional Haag-Streit 900 slit lamp without any extra attachments.

متن کامل

Estimation of optic disc size using indirect biomicroscopy.

The use of the 90 dioptre fundus lens in conjunction with slit-lamp biomicroscopy as a method of estimating optic size was evaluated in a series of 37 patients. The measurements taken from the Haag-Streit slit-lamp were compared with values obtained planimetrically in order to assess a conversion factor and also the reliability of the method. This technique is a quick and easy method of obtaini...

متن کامل

Clinical assessment of corneal endothelial cell density: an original system of grading using a slit-lamp biomicroscope.

An original system of grading of the corneal endothelial specular reflection, as assessed with a Haag-Streit 900 slit-lamp biomicroscope, has been shown to have a very highly significant relation to the endothelial cell density measured by contact specular photomicroscopy. The grading, though subjective and therefore not a substitute for the detailed record of photomicroscopy, is readily applic...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The British journal of ophthalmology

دوره 58 2  شماره 

صفحات  -

تاریخ انتشار 1974