Reliability of isometric knee extension muscle strength measurements made by a hand-held dynamometer and a belt: a comparison of two types of device

نویسنده

  • Munenori Katoh
چکیده

[Purpose] The purpose of the present study was to compare the reliability of 2 hand-held dynamometers (HHD-1, 2) with different designs, by performing isometric knee muscle extension measurements two times each. [Subjects] The subjects were 40 young healthy adults. [Methods] The reliability of the measurements was examined using Bland-Altman analysis. [Results] Bland-Altman analysis found a fixed bias in measurements made by HHD-1 with an average limits of agreement (LOA) value of -2.1 kgf. For HHD-2, only random errors were detected, and the minimal detectable change (MDC) was 11.4 kgf. Fixed biases were observed between the two devices with an average LOA value of 2.2 kgf. When the bodyweight ratio was used, fixed biases were observed in measurements made by both devices, and the average value of LOA was -0.03 kgf/kg. The comparison of the two devices revealed only random errors, and MDC was 0.22 kgf/kg. [Conclusion] For HHD measurements using these two devices, the appropriate number of measurements is two times, and comparison of measurement values between the two devices should be avoided.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reliability of Isometric Knee Extension Muscle Strength Measurements of Healthy Elderly Subjects Made with a Hand-held Dynamometer and a Belt

[Purpose] The purpose of this study was to examine the reliability of three isometric knee extension strength measurements (IKE) made with a hand-held dynamometer (HHD) and a belt of healthy elderly living in the community as subjects. [Subjects] The subject cohort consisted of 186 healthy elderly people, aged 65 to 79 years, living in local communities. [Methods] IKE of the leg subjects used t...

متن کامل

An Investigation into Reliability of Knee Extension Muscle Strength Measurements, and into the Relationship between Muscle Strength and Means of Independent Mobility in the Ward: Examinations of Patients Who Underwent Femoral Neck Fracture Surgery

[Purpose] The purpose of the present study was to investigate the reliability of isometric knee extension muscle strength measurement of patients who underwent femoral neck fracture surgery, as well as the relationship between independent mobility in the ward and knee muscle strength. [Subjects] The subjects were 75 patients who underwent femoral neck fracture surgery. [Methods] We used a hand-...

متن کامل

Validity of maximal isometric knee extension strength measurements obtained via belt-stabilized hand-held dynamometry in healthy adults

[Purpose] To determine the validity of knee extension muscle strength measurements using belt-stabilized hand-held dynamometry with and without body stabilization compared with the gold standard isokinetic dynamometry in healthy adults. [Subjects and Methods] Twenty-nine healthy adults (mean age, 21.3 years) were included. Study parameters involved right side measurements of maximal isometric k...

متن کامل

The Relationship Between Muscle Strength and Range of Motion in Lower Extremity, and Balance and Risk of Falling in the Elderly

Background: The present study examined the relationship between muscle strength and range of motion in the lower extremity, and balance and risk of falling in the elderly. Methods: This cross-sectional study was conducted on healthy elderly (mean±SD age: 65.64±4.95 y) in Rasht City, Iran. The study participants were 65 healthy male elderly who met the stud inclusion criteria. They were selecte...

متن کامل

Intra- and Inter-Rater Reliability of Micro Manual Muscle Tester of the Lower Extremity in Children With Diplegia Cerebral Palsy

Objectives: The Micro Manual Muscle Tester (MMMT) is a Hand-Held Dynamometer (HHD). The current study aimed to evaluate the intra- and inter-rater reliability of this device. Methods: To determine the reliability of the MMMT, two previously trained assessors to work with HHD performed HHD measurements on 7 muscle groups of the lower extremities (hip flexors, hip extensors, hip abductors, knee ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 27  شماره 

صفحات  -

تاریخ انتشار 2015