Terahertz pulsed imaging as an analytical tool for sustained-release tablet film coating.

نویسندگان

  • Louise Ho
  • Ronny Müller
  • Keith C Gordon
  • Peter Kleinebudde
  • Michael Pepper
  • Thomas Rades
  • Yaochun Shen
  • Philip F Taday
  • J Axel Zeitler
چکیده

The ability of terahertz pulsed imaging (TPI) to be employed as an analytical tool for monitoring a film coating unit operation and to assess the success of a subsequent process scale-up was explored in this study. As part of a process scale-up development, a total of 190 sustained-release tablets were sampled at 10% increments of the amount of polymer applied, from a lab-scale and a pilot-scale coating run. These tablets were subjected to TPI analysis, followed by dissolution testing. Information on tablet film coating layer thickness and variations in coating density were extracted using TPI. It was found that both terahertz parameters were more sensitive and informative to product quality when compared with measuring the amount of polymer applied. For monitoring the film coating unit operation, coating layer thickness showed a strong influence on the dissolution behaviour for both the lab-scale and the pilot-scale batches. An R(2) of 0.89, root mean square error (RMSE)=0.22 h (MDT range=3.21-5.48 h) and an R(2) of 0.92, RMSE=0.23 h (MDT range=5.43-8.12 h) were derived from the lab-scale and pilot-scale, respectively. The scale-up process led to significant changes in MDT between the lab-scale and pilot-scale. These changes in MDT could be explained by the differences observed in the film coating density on samples with similar amount of polymer applied between the lab and the pilot-scale. Overall, TPI demonstrated potential to be employed as an analytical tool to help refine the coating unit operation and the scale-up procedure.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Analysis of sustained-release tablet film coats using terahertz pulsed imaging.

The coating quality of a batch of lab-scale, sustained-release coated tablets was analysed by terahertz pulsed imaging (TPI). Terahertz radiation (2 to 120 cm(-1)) is particularly interesting for coating analysis as it has the capability to penetrate through most pharmaceutical excipients, and hence allows non-destructive coating analysis. Terahertz pulsed spectroscopy (TPS) was employed for th...

متن کامل

Applications of terahertz pulsed imaging to sustained-release tablet film coating quality assessment and dissolution performance.

The potential of terahertz pulsed imaging (TPI) to predict the dissolution performance in sustained-release tablets was investigated in this study. Batches of coated tablets with similar weight gain during the coating process at the lab and pilot scales were subjected to non-destructive imaging by TPI and subsequently analysed by dissolution testing. The results from the dissolution tests revea...

متن کامل

Analysis of coating structures and interfaces in solid oral dosage forms by three dimensional terahertz pulsed imaging.

Three dimensional terahertz pulsed imaging (TPI) was evaluated as a novel tool for the nondestructive characterization of different solid oral dosage forms. The time-domain reflection signal of coherent pulsed light in the far infrared was used to investigate film-coated tablets, sugar-coated tablets, multilayered controlled release tablets, and soft gelatin capsules. It is possible to determin...

متن کامل

Investigating dissolution performance critical areas on coated tablets: a case study using terahertz pulsed imaging.

During the process development of coated tablets, knowledge on the formation and the location of film coating 'weak spots' is a key factor to the success of the process and the resulting product batch. It is understood that the performance of the product batch may be greatly limited, and often compromised, by weak spots on the tablet film coat. This study uses circular, biconvex tablets to inve...

متن کامل

Quantifying Pharmaceutical Film Coating with Optical Coherence Tomography and Terahertz Pulsed Imaging: An Evaluation

Spectral domain optical coherence tomography (OCT) has recently attracted a lot of interest in the pharmaceutical industry as a fast and non-destructive modality for quantification of thin film coatings that cannot easily be resolved with other techniques. Because of the relative infancy of this technique, much of the research to date has focused on developing the in-line measurement technique ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of pharmaceutics and biopharmaceutics : official journal of Arbeitsgemeinschaft fur Pharmazeutische Verfahrenstechnik e.V

دوره 71 1  شماره 

صفحات  -

تاریخ انتشار 2009