INTRODUCTION Transcutaneous bilirubin (TcB) measurement in newborns has been studied extensively in the non-Hispanic population, but its usefulness in the Hispanic population remains unclear. We evaluate the accuracy of TcB measurements in assessing jaundice in Hispanic neonates by using total serum bilirubin (TSB) measurements as the reference standard and determine the TcB level that can be used to identify neonates at risk for clinically significant jaundice (above the 95th percentile). METHODS A total of 192 Hispanic neonates were enrolled. TcB measurements were performed within 30 minutes of obtaining the TSB measurement. The linear relationship between TcB and TSB was measured by using the Pearson correlation coefficient (r). We calculated sensitivity, specificity, and positive and negative predictive values by using a TcB level above the 75th percentile to identify neonates with a TSB level above the 95th percentile. RESULTS TSB ranged from 1.7 to 13.9 mg/dL, with 62% falling below the 75th percentile. TcB correlated well with TSB in Hispanic neonates (r = 0.87). A TcB level above the 75th percentile detected all infants with a TSB level above the 95th percentile, sensitivity 100%, and specificity 66%. CONCLUSIONS In Hispanic newborns, the TcB level correlated well with the TSB level. TcB monitoring is a useful clinical screening tool to evaluate for the risk of clinically significant jaundice.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of a new transcutaneous bilirubinometer.

OBJECTIVE The objective of this study was to evaluate the Minolta/Hill-Rom Air-Shields Transcutaneous Jaundice Meter model JM-103. METHODS We studied a convenience sample of 849 newborns > or =35 weeks of gestation in 3 hospitals. These infants had total serum bilirubin (TSB) levels measured on clinical indication, and transcutaneous bilirubin (TcB) levels were obtained within 1 hour of the T...

متن کامل

Transcutaneous bilirubinometry in preterm neonates.

This prospective study was conducted to evaluate the accuracy of transcutaneous bilirubinometry in preterm newborns less than 32 weeks of gestation. Serum bilirubin values measured by direct spectrophotometry were considered as standard, the range was 2.2-12.5 mg/dL. 32 jaundiced infants of less than 32 weeks of gestation without phototherapy, including 10 ELBW neonates, were enrolled. Close co...

متن کامل

A Comparison between Transcutaneous Bilirubin (TcB) and Total Serum Bilirubin (TSB) Measurements in Term Neonates

Background: Transcutaneous bilirubinometry (TCB) is a simple method for estimating bilirubin levels in neonates. This method is noninvasive, quick, and painless. We aimed to compare serum and cutaneous bilirubin measurements in term neonates.Method: In this descriptive cross-sectional study, 200 neonates with icter with birth weights of at least 2500 grams were studied. TCB was measured using a...

متن کامل

Comparison of Transcutaneous Bilirubin Measurement With Total Serum Bilirubin Levels in Preterm Neonates Receiving Phototherapy.

OBJECTIVE To compare transcutaneous bilirubin with total serum bilirubin in preterm neonates after initiation of phototherapy. METHODS Jaundice was assessed in 30 preterm neonates with transcutaneous bilirubin and total serum bilirubin before initiation of phototherapy and at 12 hr after initiation of phototherapy. A photo-occlusive patch was applied over the sternum. RESULTS Transcutaneous...

متن کامل

مقایسه میانگین بیلی روبین اندازه گیری شده از طریق بیلی روبینومتر با میانگین بیلی روبین سرم در نوزادان زرد

Introduction: Hyperbilirubinemia is a common benign problem in neonates. Nonetheless, if untreated, severe hyperbilirubinemia is potentially neurotoxic. The standard method for diagnosis of hyperbilirubinemia is determination of serum bilirubin levels in the laboratory that requires a blood sample which is both painful and stressful for neonates and entails cost and time. The objective of thi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American Board of Family Medicine : JABFM

دوره 20 3  شماره 

صفحات  -

تاریخ انتشار 2007