In Vivo MR Imaging of Pulmonary Perfusion and Gas Exchange in Rats via Continuous Extracorporeal Infusion of Hyperpolarized 129Xe

نویسندگان

  • Zackary I. Cleveland
  • Harald E. Möller
  • Laurence W. Hedlund
  • John C. Nouls
  • Matthew S. Freeman
  • Yi Qi
  • Bastiaan Driehuys
چکیده

BACKGROUND Hyperpolarized (HP) (129)Xe magnetic resonance imaging (MRI) permits high resolution, regional visualization of pulmonary ventilation. Additionally, its reasonably high solubility (>10%) and large chemical shift range (>200 ppm) in tissues allow HP (129)Xe to serve as a regional probe of pulmonary perfusion and gas transport, when introduced directly into the vasculature. In earlier work, vascular delivery was accomplished in rats by first dissolving HP (129)Xe in a biologically compatible carrier solution, injecting the solution into the vasculature, and then detecting HP (129)Xe as it emerged into the alveolar airspaces. Although easily implemented, this approach was constrained by the tolerable injection volume and the duration of the HP (129)Xe signal. METHODS AND PRINCIPAL FINDINGS Here, we overcome the volume and temporal constraints imposed by injection, by using hydrophobic, microporous, gas-exchange membranes to directly and continuously infuse (129)Xe into the arterial blood of live rats with an extracorporeal (EC) circuit. The resulting gas-phase (129)Xe signal is sufficient to generate diffusive gas exchange- and pulmonary perfusion-dependent, 3D MR images with a nominal resolution of 2×2×2 mm(3). We also show that the (129)Xe signal dynamics during EC infusion are well described by an analytical model that incorporates both mass transport into the blood and longitudinal relaxation. CONCLUSIONS Extracorporeal infusion of HP (129)Xe enables rapid, 3D MR imaging of rat lungs and, when combined with ventilation imaging, will permit spatially resolved studies of the ventilation-perfusion ratio in small animals. Moreover, EC infusion should allow (129)Xe to be delivered elsewhere in the body and make possible functional and molecular imaging approaches that are currently not feasible using inhaled HP (129)Xe.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Probing the regional distribution of pulmonary gas exchange through single-breath gas- and dissolved-phase 129Xe MR imaging.

Although some central aspects of pulmonary function (ventilation and perfusion) are known to be heterogeneous, the distribution of diffusive gas exchange remains poorly characterized. A solution is offered by hyperpolarized 129Xe magnetic resonance (MR) imaging, because this gas can be separately detected in the lung's air spaces and dissolved in its tissues. Early dissolved-phase 129Xe images ...

متن کامل

Hyperpolarized 129Xe MR Imaging of Alveolar Gas Uptake in Humans

BACKGROUND One of the central physiological functions of the lungs is to transfer inhaled gases from the alveoli to pulmonary capillary blood. However, current measures of alveolar gas uptake provide only global information and thus lack the sensitivity and specificity needed to account for regional variations in gas exchange. METHODS AND PRINCIPAL FINDINGS Here we exploit the solubility, hig...

متن کامل

Detection of regional radiation-induced lung injury using hyperpolarized 129Xe chemical shift imaging in a rat model involving partial lung irradiation: Proof-of-concept demonstration

Purpose The purpose of this work was to use magnetic resonance imaging (MRI) of hyperpolarized (HP) 129Xe dissolved in pulmonary tissue (PT) and red blood cells (RBCs) to detect regional changes to PT structure and perfusion in a partial-lung rat model of radiation-induced lung injury and compare with histology. Methods and materials The right medial region of the lungs of 6 Sprague-Dawley ra...

متن کامل

Temporal dynamics of hyperpolarized 129Xe resonances in living rats.

temperature, with minimal loss of its hyperpolarization after Recent development of a magnetic-resonance technique sublimation. The hyperpolarized Xe gas was transferred using hyperpolarized noble gases (He and Xe) has ento a 50 cm glass syringe prior to use. abled imaging of the lung gas space (1, 2) . While the exSprague–Dawley rats (400–500 g) were anesthetized tremely low solubility of He i...

متن کامل

Development of a hyperpolarized 129Xe system on 3T for the rat lungs.

MRI (magnetic resonance imaging) with 129Xe has gained much attention as a diagnostic methodology because of its affinity for lipids and possible polarization. The quantitative estimation of net detectability and stability of hyperpolarized 129Xe in the dissolved phase in vivo is valuable to the development of clinical applications. The goal of this study was to develop a stable hyperpolarized ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2012