Noise reduction results of an adaptive filtering technique for dual-microphone behind-the-ear hearing aids.

نویسندگان

  • Jean-Baptiste Maj
  • Jan Wouters
  • Marc Moonen
چکیده

OBJECTIVE The performance of an adaptive beam-former in a 2-microphone, behind-the-ear hearing aid for speech understanding in noisy environments was evaluated. Physical and perceptual evaluations were carried out. This was the first large-scale test of a wearable real-time implementation of this algorithm. The main perceptual research questions of this study were related to the influence on the noise reduction performance of (1) the spectro-temporal character of the jammer sound, (2) the jammer sound scene, (3) hearing impairment, and (4) the basic microphone configuration in the hearing aid. Four different speech materials were used for the perceptual evaluations. All tests were carried out in an acoustical environment comparable to living room reverberation. DESIGN The adaptive beamformer was implemented in Audallion, a small, body-worn processor, linked to a Danasound 2-microphone behind-the-ear aid. The strategy was evaluated physically in different acoustical environments. Using speech reception threshold (SRT) measurements, the processing was evaluated perceptually and the different research questions addressed with three groups of subjects. Groups I, II, and III consisted of 10 normal-hearing, 5 hearing-impaired, and 7 normal-hearing persons, respectively. The tests were carried out in three spectro-temporally different jammer sounds (unmodulated and modulated speech weighted noise, multitalker babble) and in three different noise scenarios (single noise source at 90 degrees, noise sources at 90 degrees and 270 degrees relative to speaker position, diffuse noise scene). Two microphone configurations were compared: a device equipped with two omnidirectional microphones and a device equipped with one hardware directional and one omnidirectional microphone. In each of these conditions, the adaptive beamformer and the directional and omnidirectional microphone configurations were tested. RESULTS The improvement in signal-to-noise ratio from the use of the adaptive beamformer did not depend on the spectro-temporal character of the jammer sounds and the speech materials used, although the absolute levels of the SRTs varied appreciably for different speech-noise combinations. The performance of the adaptive noise reduction depended on the jammer sound scene. CONCLUSIONS No difference in signal-to-noise ratio improvement was observed between hearing-impaired and normal-hearing listeners, although individual SRT levels may differ. On average, an SRT improvement of 7.7 and 3.9 dB for a single noise source at 90 degrees and 5.9 and 3.4 dB for two noise sources at 90 degrees and 270 degrees was obtained for both normal-hearing and hearing-impaired listeners, using the adaptive beamformer and the directional microphone, respectively, relative to the omnidirectional microphone signal. In diffuse noise, only small improvements were obtained.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

SVD-Based Optimal Filtering Technique for Noise Reduction in Hearing Aids Using Two Microphones

We introduce a new SVD-based (singular value decomposition) strategy for noise reduction in hearing aids. This technique is evaluated for noise reduction in a behind-the-ear (BTE) hearing aid where two omnidirectional microphones are mounted in an endfire configuration. The behaviour of the SVD-based technique is compared to a two-stage adaptive beamformer for hearing aids developed by Vanden B...

متن کامل

Comparison of adaptive noise reduction algorithms in dual microphone hearing aids q

In this paper, a physical and perceptual evaluation of two adaptive noise reduction algorithms for dual-microphone hearing aids are described. This is the first comparison between a fixed directional microphone on the one hand, and an adaptive directional microphone and an adaptive beamformer on the other hand, all implemented in the same digital hearing aid. The adaptive directional microphone...

متن کامل

ارزیابی عملکرد آکوستیکی مانکن سر جهت استفاده در آزمون های تعیین قدرت کاهندگی صدای وسایل حفاظت شنوایی

Introduction:One of the recommended methods for evaluation effectiveness of hearing protection is use the acoustic fixture accordance with standard ISO 4869-3. The aim of this study was evaluate the acoustic performance of fixture for using in noise reduction rate  tests of hearing protection devices in the laboratory. Methods: In this cross-sectional study , noise reduction rates o...

متن کامل

Evaluation of a second-order directional microphone hearing aid: I. Speech perception outcomes.

This clinical trial was undertaken to evaluate the benefit obtained from hearing aids employing second-order adaptive directional microphone technology, used in conjunction with digital noise reduction. Data were collected for 49 subjects across two sites. New and experienced hearing aid users were fit bilaterally with behind-the-ear hearing aids using the National Acoustics Laboratory-Nonlinea...

متن کامل

Evaluation of a second-order directional microphone hearing aid: II. Self-report outcomes.

This clinical trial was undertaken to evaluate the subjective benefit obtained from hearing aids employing automatic switching second-order adaptive directional microphone technology, used in conjunction with digital noise reduction, as compared to a fixed directional microphone or omnidirectional microphone response with the same digital noise reduction. Data were collected for 49 participants...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Ear and hearing

دوره 25 3  شماره 

صفحات  -

تاریخ انتشار 2004