"Orientation teeth" in non-mechanical laser corneal trephination for penetrating keratoplasty: 2.94 microm Er:YAG v 193 nm ArF excimer laser.

نویسندگان

  • A Behrens
  • B Seitz
  • M Küchle
  • A Langenbucher
  • M M Kus
  • C Rummelt
  • G O Naumann
چکیده

BACKGROUND/AIMS "Orientation teeth" at the donor trephination margin and correspondent "notches" at the host margin facilitate graft orientation and avoid "horizontal torsion" induced by asymmetric suture placement. In this study the quality and reproducibility of these structures created by non-mechanical laser corneal trephination were compared using two laser emissions. METHODS The procedure was performed in 20 enucleated pigs' eyes using open metal masks with eight "orientation teeth/notches" (0.3 x 0.15 mm, base x height), an automated globe rotation device, and either a 193 nm ArF excimer laser or a Q switched 2.94 microm Er:YAG laser. "Teeth/notches" were analysed by planimetry and scanning electron microscopy (SEM). RESULTS Mean size was 0.30 (0.027) x 0. 16 (0.017) mm for "teeth" and 0.30 (0.035) x 0.15 (0.021) mm for "notches" (excimer), and 0.31 (0.022) x 0.16 (0.015) mm and 0.30 (0.031) x 0.14 (0.021) mm respectively (Er:YAG). Overall, variability of notches was higher than that of teeth. By SEM, comparable cut regularity and sustained ablation profile were observed with both lasers. However, the corneal surface at the cut edge appeared slightly elevated (</=35 microm) in the Er:YAG group. CONCLUSION Orientation teeth/notches resembling those obtained with the excimer laser can be created using the Q switched Er:YAG laser, with potential advantages of lower costs, convenient equipment size, and solid state safety.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

“Orientation teeth” in non-mechanical laser corneal trephination for penetrating keratoplasty: 2.94 μm Er:YAG v 193 nm ArF excimer laser

Background/aims—“Orientation teeth” at the donor trephination margin and correspondent “notches” at the host margin facilitate graft orientation and avoid “horizontal torsion” induced by asymmetric suture placement. In this study the quality and reproducibility of these structures created by non-mechanical laser corneal trephination were compared using two laser emissions. Methods—The procedure...

متن کامل

Nonmechanical Q-switched erbium:YAG laser trephination for penetrating keratoplasty: experimental study on human donor corneas.

OBJECTIVE To assess the alterations in human donor corneal tissue induced by Q-switched erbium (Er):YAG laser corneal trephination. METHODS Thirty human corneoscleral donor buttons unsuitable for transplantation were placed in an artificial chamber on an automated rotation device. Corneas were trephined with a Q-switched Er:YAG laser (wavelength, 2.94 microm; pulse duration, 400 nanoseconds) ...

متن کامل

Corneal lathing using the excimer laser and a computer-controlled positioning system.

PURPOSE To present the excimer laser corneal shaping system (ELCS-S), an add-on device to the Keratom, a commercially available 193-nm excimer laser built by Schwind. METHODS The system is designed for the preparation of donor corneas under sterile conditions using the ultraviolet laser to offer greatest possible flexibility. Lenticules for planolamellar grafting and refractive epikeratoplast...

متن کامل

Histological comparison of corneal ablation with Er:YAG laser, Nd:YAG optical parametric oscillator, and excimer laser.

PURPOSE To use histological techniques to assess and compare the ablation depth, local damage, and surface quality of corneal ablations by a Q-switched Er:YAG laser, an optical parametric oscillator laser at 2.94 microm, a long pulse Er:YAG laser, and a 193-nm excimer laser. METHODS Human cadaver eyes and in vivo cat eyes were treated with a 6.0-mm diameter, 30-microm-deep phototherapeutic ke...

متن کامل

Penetrating Keratoplasty for Keratoconus – Excimer Versus Femtosecond Laser Trephination

BACKGROUND In case of keratoconus, rigid gas-permeable contact lenses as the correction method of first choice allow for a good visual acuity for quite some time. In a severe stage of the disease with major cone-shaped protrusion of the cornea, even specially designed keratoconus contact lenses are no more tolerated. In case of existing contraindications for intrastromal ring segments, corneal ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The British journal of ophthalmology

دوره 83 9  شماره 

صفحات  -

تاریخ انتشار 1999