The reliability of a 30-s sprint test on the Wattbike cycle ergometer.

نویسندگان

  • Matthew W Driller
  • Christos K Argus
  • Cecilia M Shing
چکیده

PURPOSE To determine the reliability of a 30-s sprint cycle test on the Wattbike cycle ergometer. METHODS Over 3 consecutive weeks, 11 highly trained cyclists (mean ± SD; age 31 ± 6 y, mass 74.6 ± 10.6 kg, height 180.5 ± 8.1cm) completed four 30-s maximal sprints on a Wattbike ergometer after a standardized warm-up. The sprint test implemented a "rolling start" that consisted of a 60-s preload (at an intensity of 4.5 W/kg) before the 30-s maximal sprint. Variables determined across the duration of the sprint were peak power (Wpeak), mean power (Wmean), W/kg, mean cadence (rpm), maximum heart rate (n = 10), and postexercise blood lactate. RESULTS The average intraclass correlation coefficients between trials (2v1, 3v2, 4v3, 4v1) were Wpeak .97 (90%CI .94-.99), Wmean .99 (90%CI .97-1.00), W/kg .96 (90%CI .91-.98), mean cadence .96 (90%CI .92-.99), maximum heart rate .99 (90%CI .97-.99), and postexercise blood lactate .94 (90%CI .87-.98). The average typical error of measurement (expressed as a CV% and absolute value between trials-2v1, 3v2, 4v3, 4v1) was Wpeak 4.9%, 52.7 W; Wmean 2.4%, 19.2 W; W/kg 2.3%, 0.18 W/kg; mean cadence 1.4%, 1.6 rpm; maximum heart rate 0.9%, 1.6 beats/min; and postexercise blood lactate 4.6%, 0.48 mmol/L. CONCLUSION A 30-s sprint test on the Wattbike cycle ergometer is highly reproducible in trained cyclists.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reliability of a 2-bout exercise test on a wattbike cycle ergometer.

PURPOSE To determine the intraday and interday reliability of a 2 × 4-min performance test on a cycle ergometer (Wattbike) separated by 30 min of passive recovery (2 × 4MMP). METHODS Twelve highly trained cyclists (mean ± SD; age = 20 ± 2 y, predicted VO2max = 59.0 ± 3.6 mL · kg-1 · min-1) completed six 2 × 4MMP cycling tests on a Wattbike ergometer separated by 7 d. Mean power was measured t...

متن کامل

Validity and reliability of the Wattbike cycle ergometer.

The purpose of this study was to assess the validity and reliability of the Wattbike cycle ergometer against the SRM Powermeter using a dynamic calibration rig (CALRIG) and trained and untrained human participants. Using the CALRIG power outputs of 50-1 250  W were assessed at cadences of 70 and 90  rev x min(-1). Validity and reliability data were also obtained from 3 repeated trials in both t...

متن کامل

Reproducibility of a Laboratory Based 1-km Wattbike Cycling Time Trial in Competitive Cyclists

The purpose of this study was to evaluate the reliability of a 1-km cycling time trial using a Wattbike cycling ergometer in competitive cyclists. Ten competitive male cyclists (mean ± SD; 63.9 ± 5.1 mL•kg -1 •min -1 ) performed a VO2max test and a familiarization of the 1-km time trial (TT) on the same day, and 3 separate 1-km TT (TT1, TT2 and TT3) separated by >24 hours. Mean performance time...

متن کامل

Effects of Ramadan observance on repeated cycle ergometer sprinting and associated inflammatory and oxidative stress responses in trained young men

Aim: was to assess the effects of Ramadan observance upon repeated sprints and associated inflammatory and oxidative stress responses. Methods: Ten young trained boxers were tested during a control period (C), at the end of the first week (R-1), and during the fourth week of Ramadan observance (R-4). On each occasion, they performed three vertical jumps, 10 x 6 s repeated sprints on a cycle erg...

متن کامل

Reliability of the Woodway Curve(TM) Non-Motorized Treadmill for Assessing Anaerobic Performance.

A curved treadmill offers a practical method of assessing anaerobic power by enabling unrestricted running motion and greater sport specificity. The purpose of this research was to determine reliability of a curved treadmill (cTM) sprint test and to compare performance measures to the traditional Wingate anaerobic power test (WAnT) performed on a cycle ergometer. Thirty-two recreationally activ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • International journal of sports physiology and performance

دوره 8 4  شماره 

صفحات  -

تاریخ انتشار 2013