A covariance structure analysis of flicker sensitivity
نویسندگان
چکیده
We tested whether linear structural models of the mechanisms underlying flicker sensitivity could reproduce the variance-covariance matrix of temporal contrast sensitivity data. Monocular sensitivities to frequencies between 2.5 and 45 Hz were measured for 124 subjects, ages 18-88 yr. Exploratory factor analyses revealed that both a two-mechanism and a three-mechanism model could adequately account for the data. Furthermore, confirmatory factor analyses and full structural equation models, using age as an explanatory variable, supported both models, with the three-factor model giving a somewhat better representation of the data. Parsimony favors the two-mechanism model. But patterns of loss associated with pre-exudative age-related maculopathy are more easily understood in terms of three underlying mechanisms.
منابع مشابه
Structure of Wavelet Covariance Matrices and Bayesian Wavelet Estimation of Autoregressive Moving Average Model with Long Memory Parameter’s
In the process of exploring and recognizing of statistical communities, the analysis of data obtained from these communities is considered essential. One of appropriate methods for data analysis is the structural study of the function fitting by these data. Wavelet transformation is one of the most powerful tool in analysis of these functions and structure of wavelet coefficients are very impor...
متن کاملVoltage Flicker Parameters Estimation Using Shuffled Frog Leaping Algorithm and Imperialistic Competitive Algorithm
Measurement of magnitude and frequency of the voltage flicker is very important for monitoring andcontrolling voltage flicker efficiently to improve the network power quality. This paper presents twonew methods for measurement of flicker signal parameters using Shuffled Frog Leaping Algorithm(SFLA) and Imperialist Competitive Algorithm (ICA). This paper estimates fundamental voltage andflicker ...
متن کاملIndividual differences in chromatic (red/green) contrast sensitivity are constrained by the relative number of L- versus M-cones in the eye
Many previous studies have shown that the relative number of long-wavelength-selective (L) versus medium-wavelength-selective (M) cones in the eye influences spectral sensitivity revealed perceptually. Here, we hypothesize that the L:M cone ratio should also influence red/green chromatic contrast sensitivity. To test this, in each subject we derived an estimate of L:M ratio based on her red/gre...
متن کاملBalance between pattern and flicker sensitivities in the visual fields of ophthalmological patients.
We measured the balance between visual sensitivities to pattern and to flicker rather than measuring absolute sensitivities to pattern or flicker. The test target was a 2-cycle deg-1 sinewave grating that was counterphase modulated at 8 Hz. Seventeen points in the visual field were tested out to eccentricities of 24 degrees. We examined 10 control subjects, 6 patients with glaucoma 10 with ocul...
متن کاملFlicker sensitivity and cardiovascular function in healthy middle-aged people.
OBJECTIVE To establish normative relations between measures of visual function and cardiovascular variables that are important for age-related disease, including various forms of glaucoma. METHODS Foveal flicker sensitivities, resting blood pressures and heart rates, and intraocular pressures were measured in 18 individuals aged 40 to 68 years. All subjects had 20/20 or better visual acuity i...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Vision Research
دوره 35 شماره
صفحات -
تاریخ انتشار 1995