Degraded and Inadequately Tested Transformer and Protective Relaying Results in Increase in Transient and Loss of Offsite Power Initiating Event Frequencies
ثبت نشده
چکیده
Significance: Dec 29, 2001 Identified By: NRC Item Type: FIN Finding DEGRADED AND INADEQUATELY TESTED TRANSFORMER AND PROTECTIVE RELAYING RESULTS IN INCREASE IN TRANSIENT AND LOSS OF OFFSITE POWER INITIATING EVENT FREQUENCIES On August 2, 2001, Unit 2 experienced a transformer failure, reactor scram, and loss of offsite power. The inspectors determined that a lightning strike in conjunction with age related degradation and inadequate testing of the Unit 2 main power transformer and switchyard protective relaying contributed to the event and resulted in an increase in the initiating event frequency for plant transients and a loss of offsite power. The inspectors determined the risk significance of this issue to be very low since all remaining mitigating systems were available to mitigate the transformer rupture, reactor scram, and loss of offsite power. Inspection Report# : 2001017(pdf)
منابع مشابه
Degraded and Inadequately Tested Transformer and Protective Relaying Results in Increase in Transient and Loss of Offsite Power Initiating Event Frequencies
Significance: Dec 29, 2001 Identified By: NRC Item Type: FIN Finding DEGRADED AND INADEQUATELY TESTED TRANSFORMER AND PROTECTIVE RELAYING RESULTS IN INCREASE IN TRANSIENT AND LOSS OF OFFSITE POWER INITIATING EVENT FREQUENCIES On August 2, 2001, Unit 2 experienced a transformer failure, reactor scram, and loss of offsite power. The inspectors determined that a lightning strike in conjunction wit...
متن کاملA New Model for Analysis of Unusual Mal-Operation of Differential Protection Due to the Ultra-Saturation Phenomenon during the Loaded Power Transformer Energization
In this paper, a new model based on the thevenin equivalent circuit for investigating the ultra-saturation phenomenon during the energization of a loaded power transformer is presented and its effect on the differential protection of the transformer is considered. The ultra-saturation phenomenon causes the mal-operation of the power transformer differential protection. So, the description a...
متن کاملA New Model for Analysis of Unusual Mal-Operation of Differential Protection Due to the Ultra-Saturation Phenomenon during the Loaded Power Transformer Energization
In this paper, a new model based on the thevenin equivalent circuit for investigating the ultra-saturation phenomenon during the energization of a loaded power transformer is presented and its effect on the differential protection of the transformer is considered. The ultra-saturation phenomenon causes the mal-operation of the power transformer differential protection. So, the description a...
متن کاملInternal Protection of Transformer Windings Against Transeint Surges Using ZnO Varistors
Power system overvoltages due to switching, lightning and other disturbances are the main problem for designers of the power transformers. Once some frequencies of the incoming surges match with some of the natural frequencies of transformer winding, the resonance phenomenon is expected in transformer winding. The resonant overvoltages may destroy the insulation between turns and cause to insul...
متن کاملMitigation Transformer Inrush Current Using Modified Transient Current Limiter
This study presents a modified transient current limiter (MTCL) for mitigation the inrush current of transformers. The MTCL is based on conventional transient current limiter (TCL), which, its configuration is modified to overcome the TCL drawbacks of operation. The proposed MTCL offers lower power losses and voltage/current THD during normal operation mode. It needs only one limiting reactor i...
متن کامل