Letters to the Editor Comment on The Radiological Physics Center's standard dataset for small field size output factors (J Appl Clin Med Phys. 2012;13(5):282‐89)

نویسندگان

  • Jakob B. Thomsen
  • Anders R. Beierholm
  • Kristian Boye
  • Jesper Carl
چکیده

Dear Editor, A standard dataset for small field output factors was published by the Radiological Physics Center (RPC).(1) The data are to be used as part of the quality control in other radiotherapy departments. As part of commissioning a new linear accelerator, we performed a comparison of our data against the original RPC dataset and found relative large deviations. We, therefore, conducted a comparison of the RPC dataset with measurements performed at four oncology departments in Denmark in order to validate the RPC dataset. The measurements were performed on Varian TrueBeam accelerators (Varian Medical Systems, Palo Alto, CA) using three different detectors all suited for small field dosimetry: a pinpoint chamber (PTW 31014; PTW, Freiburg, Germany), a prototype scintillator system developed at Technical University of Denmark,(2) and a diamond detector (PTW 60003). In addition we included some data measured on a Varian Clinac 2100C/D accelerator. Furthermore, we included output factors calculated by the treatment planning systems of the participating centers. Comparing our data to the original RPC dataset revealed a significant difference for all energies and a difference in output factors of about 2.5%. Recently an error in the original dataset was discovered, which lead to a major change in the output factors (see Followill, et al.: Erratum; Vol.15 #1). In Figs. 1 to 4, a plot of all measured and calculated values is seen for 6, 10, 15, and 18 MV beam qualities, respectively. All RPC data are taken from the corrected dataset and the error

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Using weighted power mean for equivalent square estimation

PURPOSE Equivalent Square (ES) enables the calculation of many radiation quantities for rectangular treatment fields, based only on measurements from square fields. While it is widely applied in radiotherapy, its accuracy, especially for extremely elongated fields, still leaves room for improvement. In this study, we introduce a novel explicit ES formula based on Weighted Power Mean (WPM) funct...

متن کامل

Response to Thomsen et al.: Comments on “The Radiological Physics Center's standard dataset for small field size output factors”

Delivery of accurate intensity-modulated radiation therapy (IMRT) or stereotactic radiotherapy depends on a multitude of steps in the treatment delivery process. These steps range from imaging of the patient to dose calculation to machine delivery of the treatment plan. Within the treatment planning system's (TPS) dose calculation algorithm, various unique small field dosimetry parameters are e...

متن کامل

Analysis of Accuracy of Interpolation Methods in Estimating the Output Factors for Square Fields in Medical Linear Accelerator

Introduction: To estimate the accuracy levels of Lagrange, Newton backward interpolation, and linear interpolation methods in estimating the output factors for square fields used in linear accelerator for 6 MV photons at various depths. Materials and Methods: Ionization measurements were carried out in radiation field analyzer in linear accelerator for 6 MV beams at the depths of 5 and 10 cm by...

متن کامل

Measurement Of Scatter Factors For Small Photon Fields Using Gaf chromic EBT2 Film

Introduction: Small field dosimetry is challenging for radiotherapy dosimetry. measurement of the output factor in the air and water (Sc, Scp) is one of the input parameters for commissioning of treatment planning systems and beam modeling. The aims of this study are to measured Sc,Scp for small fields with EBT2 and Ion chamber and design a appropriate mini-phantom for small fi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 15  شماره 

صفحات  -

تاریخ انتشار 2014