Correlation between Pulse Oximetry Oxygen Saturation (SpO2) and Measured Arterial Oxygen Saturation (SaO 2 ) and Arterial Oxygen Tension (PaOz) in Neonates

نویسندگان

  • Jung-Hwan Choi
  • Won Soon Park
  • Chong Ku Yun
چکیده

=Abstract=Pulse oximetry has recently been introduced as a method for continuous and non-invasive transcutaneous monitoring of arterial oxygen saturation in neonates. The purpose of our study was to determine the reliability, accuracy, and practicability of pulse oximetry for monitoring arterial oxygenation in sick newborn infants. Pulse oximetry oxygen saturation values (SpO2) were compared with simultaneously measured arterial oxygen saturation values (SaOz) by a co-oximeter. The linear regression equation for 65 data pairs was Y= 24.53 + 0.726X (r = 0.90, p ( 0.01). The difference between measured Sa02 and pulse oximetry oxygen saturation (SpOz) was 0.44% f 2.97% (mean f S.D.). The linear regression equation comparing measured SaO2 minus pulse oximetry saturation (SpO2) was Y=-23.09 + 0.258X ( ~ 0 . 5 8 , p ( 0.01). This demonstrated an increasing error of pulse oximetry with decreasing SaO2. Pulse oximetry oxygen saturation (SpOz) also correlated well with measured arterial oxygen tension (PaOz), and the upper reach of the S-shaped hemoglobin-oxygen dissociation curve was clear. With a hypothetical alarm limit set at 92%, all hyperoxemic values (29129) were correctly identified (sensitivity 100%). Of the 78 paired values, 33 were classified correctly as nonhyperoxemic (specificity 42%), and a total of 62 (29 + 33) out of the 107 paired values were ranged correctly (accuracy 58%). The accuracy increased significantly with an increase in alarm limit up to 94%, and it remained stable thereafter. We conclude that pulse oximetry is a simple, accurate, noninvasive, and continuous method of transcutaneously measuring arterial oxygen saturation, and hyperoxemia can be detected by pulse oximetry with a high sensitivity provided that prior to use, type-specific alarm limits are set.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

مقایسه اندازه‌گیری اشباع اکسیژن خون شریانی با پالس اکسی‌متری و نمونه خون شریانی در بیماران بخش مراقبت‌های ویژه قلبی

Background: Pulseoximetry is widely used in the critical care setting, currently used to guide therapeutic interventions. Few studies have evaluated the accuracy of SPO2 (puls-eoximetry oxygen saturation) in intensive care unit after cardiac surgery. Our objective was to compare pulseoximetry with arterial oxygen saturation (SaO2) during clinical routine in such patients, and to examine the eff...

متن کامل

Comparative study of pulse oximetry, physical examination and echocardiography results in the diagnosis of congenital heart defects in neonates in the first 24 hours of life

Introduction: Congenital heart disease is the most common congenital anomaly. About 50% of Neonates with congenital heart disease are asymptomatic in the first few days of life and are not diagnosed on initial examination. Pulse oximetry is a non-invasive method that can show the percentage of oxygen saturation in the blood and congenital heart disease. Methods: This was a descriptive cross-se...

متن کامل

Evaluation of Pulse Oximetry in the Early Detection of Congenital Heart Diseases in Newborns

Background: Congenital heart diseases, which are asymptomatic at birth, are the most important causes of infant mortality. This study aimed to evaluate the role of pulse oximetry in the early detection of congenital heart diseases among newborns.Methods: In this cross-sectional descriptive study, 1230 newborns who were born in university hospitals in an urban area of Iran were placed unde...

متن کامل

Validation of Oxygen Saturation Monitoring In

www.ajcconline.org • BACKGROUND Pulse oximetry is commonly used to monitor oxygenation in neonates, but cannot detect variations in hemoglobin. Venous and arterial oxygen saturations are rarely monitored. Few data are available to validate measurements of oxygen saturation in neonates (venous, arterial, or pulse oximetric). • PURPOSE To validate oxygen saturation displayed on clinical monitors ...

متن کامل

The association between forced expiratory volume in one second (FEV1) and pulse oximetric measurements of arterial oxygen saturation (SpO2) in the patients with COPD: A preliminary study

BACKGROUND The study was aimed to explore the association between arterial oxygen saturation (SpO2) and spirometer parameters of disease severity in chronic obstructive pulmonary disease (COPD) patients with a view to identify whether the pulse oximetry can be used as an alternative to arterial values in the clinical management of COPD patients in a routine practice. MATERIALS AND METHODS Thi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009