Accuracy of detection of carboxyhemoglobin and methemoglobin in human and bovine blood with an inexpensive, pocket-size infrared scanner
نویسندگان
چکیده
Detecting life-threatening common dyshemoglobins such as carboxyhemoglobin (COHb, resulting from carbon monoxide poisoning) or methemoglobin (MetHb, caused by exposure to nitrates) typically requires a laboratory CO-oximeter. Because of cost, these spectrophotometer-based instrument are often inaccessible in resource-poor settings. The aim of this study was to determine if an inexpensive pocket infrared spectrometer and smartphone (SCiO®Pocket Molecular Sensor, Consumer Physics Ltd., Israel) accurately detects COHb and MetHb in single drops of blood. COHb was created by adding carbon monoxide gas to syringes of heparinized blood human or cow blood. In separate syringes, MetHb was produced by addition of sodium nitrite solution. After incubation and mixing, fractional concentrations of COHb or MetHb were measured using a Radiometer ABL-90 Flex® CO-oximeter. Fifty microliters of the sample were then placed on a microscope slide, a cover slip applied and scanned with the SCiO spectrometer. The spectrograms were used to create simple linear models predicting [COHb] or [MetHb] based on spectrogram maxima, minima and isobestic wavelengths. Our model predicted clinically significant carbon monoxide poisoning (COHb ≥15%) with a sensitivity of 93% and specificity of 88% (regression r2 = 0.63, slope P<0.0001), with a mean bias of 0.11% and an RMS error of 21%. Methemoglobinemia severe enough to cause symptoms (>20% MetHb) was detected with a sensitivity of 100% and specificity of 71% (regression r2 = 0.92, slope P<0.001) mean bias 2.7% and RMS error 21%. Although not as precise as a laboratory CO-oximeter, an inexpensive pocket-sized infrared scanner/smartphone detects >15% COHb or >20% MetHb on a single drop of blood with enough accuracy to be useful as an initial clinical screening. The SCiO and similar relatively low cost spectrometers could be developed as inexpensive diagnostic tools for developing countries.
منابع مشابه
Measurement of carboxyhemoglobin and methemoglobin by pulse oximetry: a human volunteer study.
BACKGROUND A new eight-wavelength pulse oximeter is designed to measure methemoglobin and carboxyhemoglobin, in addition to the usual measurements of hemoglobin oxygen saturation and pulse rate. This study examines this device's ability to measure dyshemoglobins in human volunteers in whom controlled levels of methemoglobin and carboxyhemoglobin are induced. METHODS Ten volunteers breathed 50...
متن کاملDetection and discrimination of two Brucella species by multiplex real-time PCR and high-resolution melt analysis curve from human blood and comparison of results using RFLP
Objective(s): Rapid and accurate detection of Brucella abortus and Brucella melitensis from clinical samples is so important because antibiotic treatment has major side effects. This study reveals a new method in detection of clinical samples of brucellosis using real-time PCR and high-resolution melt (HRM) curve analysis. Materials and Methods: 160 brucellosis suspicious samples with more tha...
متن کاملStudies of Methemoglobin Concentrations of Three Human Erythrocyte Genotypes (Hb AA, Hb AS, and Hb SS) in the Presence of Five Antimalarial Drugs
Background: Malaria remains the world’s most devastating human parasitic infection. Our goal was to assess the capacity of increasing concentrations of five antimalarial drugs (FansidarTM, HalfanTM, Quinine, CoartemTM and Chloroquine phosphate) to elicit the generation of methemoglobin in three human erythrocyte genotypes (Hb AA, Hb AS and Hb SS). Materials and Methods: Spectrophotometric metho...
متن کاملThe spectrophotometric measurement of carboxyhemoglobin.
A simple, reliable and rapid method for the spectrophotometric determina tion of carboxyhemoglobin in fresh blood is described. A blood hemolysate is prepared by diluting a blood sample with 0.4 percent NH4 OH. Addition of sodium dithionite deoxygenates hemoglobin (and reduces methemoglobin if present) without affecting carboxyhemoglobin. Comparison of the 541/555 nm absorbance ratio for the h...
متن کاملDevelopment of methemoglobin-based biological dosimetry in gamma–irradiated mice
Background: A new biological dosimeter based on methemoglobin level was developed in this study. Materials and Methods: Methemoglobin level in erythrocytes from mice subjected to &gamma rays from a 60Co source was detected using the methemoglobin kit. The dose range was from 0.5 to 8 Gy and the dose rate was 0.5 Gy/min. Results: The results demonstrate that methemoglobin level increases with in...