Bioavailability of inhaled fluticasone propionate via chambers/masks in young children.

نویسندگان

  • K Blake
  • R Mehta
  • T Spencer
  • R L Kunka
  • L Hendeles
چکیده

We determined lung bioavailability of a fluticasone propionate (FP) pressurised metred-dose inhaler (Flovent HFA; GlaxoSmithKline, Research Triangle Park, NC, USA) administered via AeroChamber Plus (Monaghan Medical, Plattsburgh, NY, USA) with Facemask and Babyhaler (GlaxoSmithKline) valved holding chambers (VHCs) using a population pharmacokinetic approach. Children from 1 to <4 yrs of age with stable asthma but a clinical need for inhaled corticosteroid therapy were administered 88 μg FP hydrofluoroalkane (2 × 44 μg) twice daily delivered through the two devices in an open-label, randomised crossover manner for 8 days each. Patients were randomised to one of three sparse sampling schedules for blood collection throughout the 12-h dosing interval on the 8th day of each treatment for pharmacokinetic analysis. The area under the FP plasma concentration-time curve (AUC) was determined for each regimen. 17 children completed the study. The population mean AUC following FP with AeroChamber Plus with Facemask was 97.45 pg·h·mL(-1) (95% CI 85.49-113.32 pg·h·mL(-1)) and with Babyhaler was 51.55 pg·h·mL(-1) (95% CI 34.45-64.46 pg·h·mL(-1)). The relative bioavailability (Babyhaler/AeroChamber Plus) was 0.53 (95% CI 0.30-0.75). Clinically significant differences in lung bioavailability were observed between the devices. VHCs are not interchangeable, as differences in drug delivery to the lung may occur. A population pharmacokinetic approach can be used to determine lung bioavailability of FP.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Decreased cortisol response to insulin induced hypoglycaemia in asthmatics treated with inhaled fluticasone propionate.

AIMS To assess adrenal function in asthmatic children treated with inhaled fluticasone propionate for up to 16 weeks. METHODS Children with asthma and bronchial hyperresponsiveness to inhaled methacholine were treated with inhaled fluticasone 250-750 microg/day via Volumatic spacer. The insulin tolerance test (ITT) was performed to assess adrenal function. RESULTS Eighteen asthmatic patient...

متن کامل

LETTERS TO THE EDITOR Montelukast and Churg-Strauss syndrome

I read with interest the case report by Tuggey and Hosker where Churg-Strauss syndrome was associated with the use of montelukast in an asthmatic patient in whom there was no recent exposure to oral corticosteroid. However, it is worth noting that the patient was using a high dose of inhaled fluticasone propionate (1.5 mg/day) via a large volume spacer prior to the introduction of montelukast. ...

متن کامل

Montelukast and Churg-Strauss syndrome

I read with interest the case report by Tuggey and Hosker where Churg-Strauss syndrome was associated with the use of montelukast in an asthmatic patient in whom there was no recent exposure to oral corticosteroid. However, it is worth noting that the patient was using a high dose of inhaled fluticasone propionate (1.5 mg/day) via a large volume spacer prior to the introduction of montelukast. ...

متن کامل

Adrenal suppression with inhaled budesonide and fluticasone propionate given by large volume spacer to asthmatic children.

BACKGROUND The aim of this study was to compare the systemic bioactivity of inhaled budesonide (B) and fluticasone propionate (F), each given by large volume spacer, on a microgram equivalent basis in asthmatic children. METHODS Ten stable asthmatic children of mean age 11 years and forced expiratory volume in one second (FEV1) 81.6% predicted, who were receiving treatment with < or = 400 mic...

متن کامل

Comparison of pharmacokinetics and systemic effects of inhaled fluticasone propionate in patients with asthma and healthy volunteers: a randomised crossover study.

BACKGROUND Inhaled corticosteroids are currently the cornerstone of asthma treatment. Some studies of high-dose fluticasone propionate in patients with no or mild asthma have, however, suggested substantial systemic absorption. We investigated the pharmacokinetics of fluticasone propionate in patients with asthma receiving appropriate doses for severity. METHODS We did a double-blind, randomi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The European respiratory journal

دوره 39 1  شماره 

صفحات  -

تاریخ انتشار 2012