A digital method for separation and reconstruction of pile-up events in germanium detectors.
نویسندگان
چکیده
The problem of pulse pile-up is very often encountered in precise measurements of γ-rays using germanium detectors. The standard method of treating the pile-up events is to identify and reject them using an appropriate electronic system. Digital acquisition techniques now allow the recording of waveforms of pile-up events that can be analyzed and the contributing single pulses recovered, rather than simply tolerating the losses associated with pile-up. In this paper, a method for the off-line digital processing of pile-up events from germanium detectors is demonstrated. The method is based on an appropriate fitting of the detector signals, shaped with a suitable digital pulse shaper. It is shown that the method is able to recover the pile-up events with good accuracy even when the constituent signals are in close proximity. The method is very useful for γ-ray spectroscopy in nuclear physics experiments, where the low intensity signals can be lost due to the pile-up in a high-rate environment.
منابع مشابه
Direct measurement of product of the electron mobility and mean free drift time of CdZnTe semiconductors using position sensitive single polarity charge sensing detectors
Related Articles A new detector for mass spectrometry: Direct detection of low energy ions using a multi-pixel photon counter Rev. Sci. Instrum. 83, 013304 (2012) A transport-based model of material trends in nonproportionality of scintillators J. Appl. Phys. 109, 123716 (2011) A digital method for separation and reconstruction of pile-up events in germanium detectors Rev. Sci. Instrum. 81, 103...
متن کاملComparisons Between Digital Gamma Ray Spectrometer (DSPEC) and Standard Nuclear Instrumentation Methods (NIM) Systems
Up until about a year ago, gamma-ray spectroscopy has always been done using the analog amplifier, which processes the pulses from the preamplifier to remove the noise, reject the pile-up signals, and shape the signals into some desirable form before sending them to the analog-to-digital converter (ADC) to be digitized. In late 1996, EG&G Ortec introduced a digital gamma-ray spectrometer (DSPec...
متن کاملکاربرد روش فعال سازی نوترونی در کشف مواد منفجره پلاستیکی
In this work, the ability of neuron probes to detect to plastic bombs in airway luggage or postal parcels has been investigated. As explosives are rich in nitrogen, 10.83 MeV gamma radiations may be employed to detect this nitrogen. First, the method is studied theoretically by using the Monte-Carlo simulation method and the MCNP code. The optimum distance, the positions of the detector and t...
متن کاملFast digitizing techniques applied to scintillation detectors
A 200 MHz 12-bit fast transient recorder card has been used for the digitization of pulses from photomultipliers coupled to organic scintillation detectors. Two modes of operation have been developed at ENEA-Frascati: a) continuous acquisition up to a maximum duration of ∼ 1.3 s corresponding to the full on-board memory (256 MSamples) of the card: in this mode, all scintillation events are reco...
متن کاملFast System Matrix Calculation in CT Iterative Reconstruction
Introduction: Iterative reconstruction techniques provide better image quality and have the potential for reconstructions with lower imaging dose than classical methods in computed tomography (CT). However, the computational speed is major concern for these iterative techniques. The system matrix calculation during the forward- and back projection is one of the most time- cons...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Review of scientific instruments
دوره 81 10 شماره
صفحات -
تاریخ انتشار 2010