Determination of lead in seawater by flow-injection on-line preconcentration-electrothermal atomic absorption spectrometry after coprecipitation with iron(III) hydroxide.

نویسندگان

  • Junichi Nakajima
  • Yoshihiro Hirano
  • Koichi Oguma
چکیده

A flow-injection on-line preconcentration-electrothermal atomic absorption spectrometric (ETAAS) method coupled with a coprecipitation method has been developed for the determination of lead in seawater. The combination of two preconcentration procedures, coprecipitation with iron(II) hydroxide and solid-phase extraction with a lead-selective resin, Pb-Spec, allowed the determination of lead at the ng kg(-1) level. Lead in 250 g of a sample solution was collected by coprecipitation with 10 mg of iron. The precipitate was dissolved in 25 ml of 1 mol l(-1) nitric acid; then, a 4-ml aliquot of the sample solution was introduced into the flow-injection system to preconcentrate and separate lead from iron on a Pb.Spec microcolumn. The sorbed lead was eluted with a 1.0 x 10(-4) mol l(-1) EDTA solution. The 30-microl portion of the eluate corresponding to the highest analyte concentration zone was injected into a graphite furnace. The overall enhancement factor was about 200 for 250 g of the sample. The average and standard deviation of ten blank values obtained were 1.7 ng and 0.38 ng, respectively. The recovery was 93.7 +/- 5.0% for seawater spiked with 20 ng kg(-1) lead. The proposed method is applicable to the analysis of seawater for lead at slightly higher levels.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of Aluminum in Dialysis Concentrates by Atomic Absorption Spectrometry after Coprecipitation with Lanthanum Phosphate

This method was developed for the determination of trace amounts of aluminum(III) in dialysis concentrates using atomic absorption spectrometry after coprecipitation with lanthanum phosfate. The analytical parameters that influenced the quantitave coprecipitation of analyte including amount of lanthanum, amount of phosfate, pH and duration time were optimized. The % recoveries of the analyte io...

متن کامل

Determination of Aluminum in Dialysis Concentrates by Atomic Absorption Spectrometry after Coprecipitation with Lanthanum Phosphate

This method was developed for the determination of trace amounts of aluminum(III) in dialysis concentrates using atomic absorption spectrometry after coprecipitation with lanthanum phosfate. The analytical parameters that influenced the quantitave coprecipitation of analyte including amount of lanthanum, amount of phosfate, pH and duration time were optimized. The % recoveries of the analyte io...

متن کامل

Determination of Cadmium by Electrothermal Atomic Absorption Spectrometry after its Separation and Preconcentration by Syringe to Syringe Dispersive Liquid Phase Microextraction-Solidified Floating Organic Drop

The application of syringe to syringe dispersive liquid phase microextraction-solidified floating organic drop was extended for the separation and preconcentration of trace amounts of cadmium ions from water and cereal samples. The extracted cadmium was quantified by electrothermal atomic absorption spectrometry. Factors affecting the complex formation as well as microextraction efficiency such...

متن کامل

Determination of chromium, copper and lead in river water by graphite-furnace atomic absorption spectrometry after coprecipitation with terbium hydroxide.

Coprecipitation with terbium hydroxide quantitatively recovered trace amounts of chromium(III), copper(II) and lead(II) at pH 8.4 - 10.8, 8.0 - 11.5 and 8.7 - 11.5, respectively. The precipitate was dissolved in 0.85 mol dm(-3) nitric acid, and the analytes were determined by graphite-furnace atomic absorption spectrometry (GF-AAS). The presence of terbium (up to 7 g dm(-3)) did not interfere w...

متن کامل

Atomic Absorption Spectrometric Determination of Lead after Extraction and Preconcentration with 5-Br-PADAP

Lead is quantitatively retained on 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol (5-Br-PADAP)-ammonium tetraphenylborate with microcrystalline naphthalene or by a column method in the pH range 4.0-6.0 from a large volume of aqueous solutions of various samples with preconcentration factor of 60. After filtration, the solid mass consisting of the lead complex and naphthalene was dissolved wi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical sciences : the international journal of the Japan Society for Analytical Chemistry

دوره 19 4  شماره 

صفحات  -

تاریخ انتشار 2003