Adaptive Optics Calibration for a Wide-Field Microscope
نویسندگان
چکیده
Adaptive optics calibration of a novel wide-field scanning microscope is described, comparing relevant parameters for several optimization techniques. Specifically, comparisons of the optimization algorithm, image quality metrics, and the calibration image target are detailed. It is shown that stochastic parallel gradient descent (SPGD) algorithm using image intensity as a metric provides robust, repeatable system optimization. Results also show that optimization performance improves when the feature sizes on the calibration target approach the diffraction limit and are more uniformly distributed. This paper further compares stochastic, image-based optimization performance to that of conventional adaptive optics optimization with a point source object and a Shack Hartmann wavefront sensor.
منابع مشابه
Adaptive optics for fluorescence wide-field microscopy using spectrally independent guide star and markers.
We describe the implementation and use of an adaptive optics loop in the imaging path of a commercial wide field microscope. We show that it is possible to maintain the optical performances of the original microscope when imaging through aberrant biological samples. The sources used for illuminating the adaptive optics loop are spectrally independent, in excitation and emission, from the sample...
متن کاملImage-based calibration of a deformable mirror in wide-field microscopy.
Optical aberrations limit resolution in biological tissues, and their influence is particularly large for promising techniques such as light-sheet microscopy. In principle, image quality might be improved by adaptive optics (AO), in which aberrations are corrected by using a deformable mirror (DM). To implement AO in microscopy, one requires a method to measure wavefront aberrations, but the mo...
متن کاملModelling the application of adaptive optics to wide-field microscope live imaging.
Wide-field fluorescence microscopy is an essential tool in modern cell biology. Unfortunately the image quality of fluorescence microscopes is often significantly degraded due to aberrations that occur under normal imaging conditions. In this article, we examine the use of adaptive optics technology to dynamically correct these problems to achieve close to ideal diffraction limited performance....
متن کاملClosed loop adaptive optics for microscopy without a wavefront sensor.
A three-dimensional wide-field image of a small fluorescent bead contains more than enough information to accurately calculate the wavefront in the microscope objective back pupil plane using the phase retrieval technique. The phase-retrieved wavefront can then be used to set a deformable mirror to correct the point-spread function (PSF) of the microscope without the use of a wavefront sensor. ...
متن کاملHigh numerical aperture holographic microscopy reconstruction with extended z range.
A holographic microscopy reconstruction method compatible with a high numerical aperture microscope objective (MO) up to NA=1.4 is proposed. After off-axis and reference field curvature corrections, and after selection of the +1 grating order holographic image, a phase mask that transforms the optical elements of the holographic setup into an afocal device is applied in the camera plane. The re...