Rate nephelometry and radial immunodiffusion compared for measuring serum prealbumin.
نویسندگان
چکیده
We compared a rate-nephelometric method and a radial immunodiffusion (RID) assay for measurement of prealbumin (transthyretin) in 55 samples of serum from healthy children. The mean prealbumin concentration as measured by the Beckman Auto ICS nephelometer was 188 mg/L (range 128-350); the mean by RID was 221 mg/L (range 125-419). This difference was statistically significant by Student's t-test (p less than 0.05), but the correlation coefficient (r) was 0.95. To determine a reference interval for prealbumin in children by the Auto ICS method, we assayed samples from 93 healthy children between the ages of one day and 18 years (55 boys, 38 girls). The mean was 191 mg/L, the reference interval (mean +/- 2 SD) 109-273 mg/L. There was no significant difference in prealbumin concentrations between girls and boys (Student's t-test, p greater than 0.05). Evidently the Beckman Auto ICS method measures prealbumin in serum rapidly and accurately.
منابع مشابه
Three immunoassay methods evaluated for quantifying prealbumin (transthyretin) in serum.
We developed an immunoturbidimetric assay for prealbumin on the Cobas Bio centrifugal analyzer and compared results from this assay with those from a rate nephelometric assay (Beckman Instruments Inc.) and a radial immunodiffusion kit (Behring Diagnostics). All three assays were evaluated for precision, linearity, and correlation to each other for analysis of sera from pediatric patients. All a...
متن کاملAutomated rate-immunonephelometric determination of serum prealbumin (transthyretin).
We describe an automated determination of serum prealbumin (transthyretin), based on the maximum rate of light scatter of an antigen-antibody precipitate. Optimal dilutions of antibody reagent and of 100-microL serum samples are given. Within- and between-assay CVs are less than 5%. Results by this method are nearly identical with those obtained by a radial-immunodiffusion technique. Measuring ...
متن کاملComparison of radial immunodiffusion and laser nephelometry for quantitating some serum proteins.
After quantitating immunoglobulins G, A, and M and complement C3c and C4 in serum by using a laser nephelometer coupled with a data processor, I compared these results with values obtained by an early-readout radial immunodiffusion method. Day-to-day precision was better for nephelometry than for radial immunodiffusion for all proteins analyzed. The average coefficient of variation was 6.0% for...
متن کاملLaser nephelometric measurement of seven serum proteins compared with radial immunodiffusion.
Quantification of immunoglobulins IgG, IgA, IgM, C3 complement, siderophilin, alpha 2-macroglobulin and haptoglobin in serum by a Behring laser nephelometer coupled with a date processing apparatus was compared with values obtained by the radial immunodiffusion method of Mancini. The precision was not improved by the use of the laser nephelometer as compared to Mancini radial immunodiffusion, b...
متن کاملUse of laser nephelometry in the measurement of serum proteins.
Measurement of immunoglobulins (Ig) and of complement component C3 in human serum by automated and manual nephelometric techniques is tedious, and the effective linear range is too narrow. We describe a laser nephelometer/reagent system for measuring serum proteins by the use of forward light scatter (which enhances the ratio of reaction/blank), electronic blank subtraction, laser light (632 nm...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 33 1 شماره
صفحات -
تاریخ انتشار 1987