Association of homocysteine and smoking with cerebral microemboli in patients with mechanical heart valves: a transcranial Doppler study
نویسندگان
چکیده
Objectives Microembolic signals (MES) on transcranial Doppler (TCD) predict stroke and cognitive decline. Plasma levels of total homocysteine (tHcy), a prothrombotic factor, are higher in patients with microemboli in carotid stenosis and in patients with paradoxical embolism. In this study we assessed the association between the level of tHcy and the number of MES in patients with mechanical heart valves (MHVs). Methods TCD monitoring was performed to detect MES before and after breathing 100% oxygen and repeated every 2-4 weeks up to six times. Results Twenty-five patients with MHVs (mean age: 63.60±10.15 years) participated in this study; 15 were men (66.47±7.25 years) and 10 were women (59.30±12.60 years). In total, there were 126 study visits. In multiple regression, higher tHcy was associated with more MES in both preoxygenation (OR 1.34 (95% CI 1.07 to 1.68, P=0.009)) and postoxygenation (OR 1.40 (95% CI 1.07 to 1.83, P=0.01)) phases. Current smoking and the length of time between the operation and monitoring also correlated with a higher number of MES before and after breathing oxygen, particularly in women. Conclusions Higher tHcy and smoking were associated with a higher MES count in both preoxygenation and postoxygenation phases. Because smoking can be stopped and hyperhomocysteinaemia is treatable, these are clinically important findings.
منابع مشابه
Solid cerebral microemboli and cerebrovascular symptoms in patients with prosthetic heart valves.
BACKGROUND AND PURPOSE Although cerebral microemboli are often detected by transcranial Doppler ultrasonography in mechanical heart valve patients, the clinical significance of such microemboli is unclear. The aim of this study was to determine the frequency and composition of cerebral microemboli in a prosthetic heart valve population and to correlate these findings to cerebrovascular symptoms...
متن کاملOnline automatic discrimination between solid and gaseous cerebral microemboli with the first multifrequency transcranial Doppler.
BACKGROUND AND PURPOSE The aim of this study was to assess the first multifrequency transcranial Doppler system that was specially developed to automatically detect and discriminate between solid and gaseous cerebral microemboli. METHODS The multifrequency transcranial Doppler instrumentation insonates simultaneously with 2.5 and 2.0 MHz. Differentiation between solid and gaseous microemboli ...
متن کاملTranscranial Doppler application for risk assessment of stroke in patients with mechanical mitral valve
Introduction: Observing microembolic signals in brain vessels by transcranial Doppler technology is a very common finding in patients with mechanical heart valve. These signals are almost always clinically asymptomatic. The aim of this study was assessment of transcranial Doppler in detecting probability of stroke in patients with mechanical heart valve. Methods: This descriptive study was ca...
متن کاملIncidence of transcranial Doppler-detected cerebral microemboli in patients referred for echocardiography.
BACKGROUND AND PURPOSE Transcranial Doppler can detect cerebral microemboli. These emboli may be a risk factor for embolic stroke. We studied the prevalence of microemboli in patients referred for echocardiography. METHODS Forty-two patients were evaluated. Patients were studied with continuous monitoring over one middle cerebral artery for 30 minutes, and the number of microemboli was record...
متن کاملAutomatic online embolus detection and artifact rejection with the first multifrequency transcranial Doppler.
BACKGROUND AND PURPOSE The goal of this study was to assess the first multifrequency transcranial Doppler system specially developed for online automatic detection of cerebral microemboli. METHODS The multifrequency Doppler instrumentation insonates simultaneously with 2.0- and 2.5-MHz frequencies. The detection threshold for embolus detection used in this study was a relative Doppler energy ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 2 شماره
صفحات -