An Asymmetric Birdcage Coil for Small-animal MR Imaging at 7T
نویسندگان
چکیده
The birdcage (BC) coil is currently being utilized for uniform radiofrequency (RF) transmit/receive (Tx/Rx) or Tx-only configuration in many magnetic resonance (MR) imaging applications, but insufficient magnetic flux (|B1|) density and their non-uniform distribution still exists in high-field (HF) environments. We demonstrate that the asymmetric birdcage (ABC) transmit/receive (Tx/Rx) volume coil, which is a modified standard birdcage (SBC) coil with the end ring split into two halves, is suitable for improving the |B1| sensitivity in 7T small-animal MR imaging. Cylindrical SBC and ABC coils with 35 mm diameter were constructed and bench tested for mouse body MR imaging at 300 MHz using a 7T scanner. To assess the ABC coil performance, computational electromagnetic (EM) simulation and 7T MR experiment were performed by using a cylindrical phantom and in vivo mouse body and quantitatively compared with the SBC coil in terms of |B1| distribution, RF transmit (|B1+|) field, and signal-to-noise ratio (SNR). The bench measurements of the two BC coils are similar, yielding a quality value (Q-value) of 74.42 for the SBC coil and 77.06 for the ABC coil. The computational calculation results clearly show that the proposed ABC coil offers superior |B1| field and |B1+| field sensitivity in the central axial slice compared with the SBC coil. There was also high SNR and uniformly distributed flip angle (FA) under the loaded condition of mouse body in the 7T experiment. Although ABC geometry allows a further increase in the |B1| field and |B1+| field sensitivity in only the central axial slice, the geometrical modification of the SBC coil can make a high performance RF coil feasible in the central axial slice and also make target imaging possible in the diagonal direction.
منابع مشابه
Design and numerical evaluation of a volume coil array for parallel MR imaging at ultrahigh fields.
In this work, we propose and investigate a volume coil array design method using different types of birdcage coils for MR imaging. Unlike the conventional radiofrequency (RF) coil arrays of which the array elements are surface coils, the proposed volume coil array consists of a set of independent volume coils including a conventional birdcage coil, a transverse birdcage coil, and a helix birdca...
متن کاملDesign and Simulation of a Birdcage Coil using CST Studio Suite for Application at 7T
This work describes the study of coil for Magnetic Resonance Imaging (MRI) application. Concretely, the principal objective is the design of a birdcage coil (RF coil) to use in a 7 Tesla scanner. More strength field has a better SNR and increased chemical shift effects, improving spectral fat suppression and spectroscopy. Moreover, a better SNR increases the spatial resolution or reduces the im...
متن کاملA 7T 8 channel transmit-receive dipole array for head imaging: dipole element and coil evaluation
Target audience: Radiofrequency (RF) engineers, anyone interested in high field RF coils, parallel transmit or high field brain imaging. Introduction: Electric dipole antennas are seeing increasing use for 7T MR imaging. They differ from conventional surface coil loops in many ways. With 8 elements surrounding a body sized tissue equivalent phantom and array of dipole antennas can achieve highe...
متن کاملDesign of Crisscrossed Double-Layer Birdcage Coil for Improving B1 + Field Homogeneity for Small-Animal Magnetic Resonance Imaging at 300 MHz
We design a crisscrossed double-layer birdcage (DLBC) coil by modifying the coil geometry of a standard single-layer BC (SLBC) coil to enhance the homogeneity of transmitting magnetic flux density (B1 ) along the main magnetic field (B0)-direction for small-animal magnetic resonance imaging (MRI) at 300 MHz. The performance assessment of the crisscrossed DLBC coil is conducted by computational ...
متن کاملUsing a whole-body 31P birdcage transmit coil and 16-element receive array for human cardiac metabolic imaging at 7T
PURPOSE Cardiac phosphorus magnetic resonance spectroscopy (31P-MRS) provides unique insight into the mechanisms of heart failure. Yet, clinical applications have been hindered by the restricted sensitivity of the surface radiofrequency-coils normally used. These permit the analysis of spectra only from the interventricular septum, or large volumes of myocardium, which may not be meaningful in ...