Evidence-based guideline update: intraoperative spinal monitoring with somatosensory and transcranial electrical motor evoked potentials*.

نویسندگان

  • Marc R Nuwer
  • Ronald G Emerson
  • Gloria Galloway
  • Alan D Legatt
  • Jaime Lopez
  • Robert Minahan
  • Thoru Yamada
  • Douglas S Goodin
  • Carmel Armon
  • Vinay Chaudhry
  • Gary S Gronseth
  • Cynthia L Harden
چکیده

OBJECTIVE To evaluate whether spinal cord intraoperative monitoring (IOM) with somatosensory and transcranial electrical motor evoked potentials (EPs) predict adverse surgical outcomes. METHODS A panel of experts reviewed the results of a comprehensive literature search and identified published studies relevant to the clinical question. These studies were classified according to the evidence-based methodology of the American Academy of Neurology. Objective outcomes of postoperative onset of paraparesis, paraplegia, and quadriplegia were used because no randomized or masked studies were available. RESULTS AND RECOMMENDATIONS Four class I and eight class II studies met inclusion criteria for analysis. The four class I studies and seven of the eight class II studies reached significance in showing that paraparesis, paraplegia, and quadriplegia occurred in the IOM patients with EP changes compared with the IOM group without EP change. All studies were consistent in showing all occurrences of paraparesis, paraplegia, and quadriplegia in the IOM patients with EP changes, with no occurrences of paraparesis, paraplegia, and quadriplegia in patients without EP change. In the class I studies, 16% to 40% of the IOM patients with EP changes developed postoperative-onset paraparesis, paraplegia, or quadriplegia. IOM is established as effective to predict an increased risk of the adverse outcomes of paraparesis, paraplegia, and quadriplegia in spinal surgery (four class I and seven class II studies). Surgeons and other members of the operating team should be alerted to the increased risk of severe adverse neurologic outcomes in patients with important IOM changes (level A).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Specialty Section on Surgical Neuromonitoring INTRAOPERATIVE MONITORING OF SEGMENTAL SPINAL NERVE ROOT FUNCTION WITH FREE-RUN AND ELECTRICALLY-TRIGGERED ELECTROMYOGRAPHY AND SPINAL CORD FUNCTION WITH REFLEXES AND F-RESPONSES A POSITION STATEMENT BY THE AMERICAN SOCIETY OF NEUROPHYSIOLOGICAL MONITORING

Background Context. Orthodromic ascending somatosensory evoked potentials and antidromic descending neurogenic somatosensory evoked potentials monitor spinal cord sensory function. Transcranial motor stimulation monitors spinal cord motor function but only activates 4–5% of the motor units innervating a muscle. Therefore, 95–96% of the motor spinal cord systems activating the motor units are no...

متن کامل

Evidence-based guideline update: Intraoperative spinal monitoring with somatosensory and transcranial electrical motor evoked potentials. Report of the Therapeutics and Technology Assessment Subcommittee of the American Academy of Neurology and the American Clinical Neurophysiology Society.

EVIDENCE-BASED GUIDELINE UPDATE: INTRAOPERATIVE SPINAL MONITORING WITH SOMATOSENSORY AND TRANSCRANIAL ELECTRICAL MOTOR EVOKED POTENTIALS: REPORT OF THE THERAPEUTICS AND TECHNOLOGY ASSESSMENT SUBCOMMITTEE OF THE AMERICAN ACADEMY OF NEUROLOGY AND THE AMERICAN CLINICAL NEUROPHYSIOLOGY SOCIETY John P. Ney, David N. van der Goes, Seattle: Nuwer et al.1 consolidated the best evidence available on the...

متن کامل

ACNS Guideline: Transcranial Electrical Stimulation Motor Evoked Potential Monitoring.

Motor evoked potentials (MEPs) are electrical signals recorded from neural tissue or muscle after activation of central motor pathways. They complement other clinical neurophysiology techniques, such as somatosensory evoked potentials (SEPs), in the assessment of the nervous system, especially during intraoperative neurophysiologic monitoring (IONM). Somatosensory evoked potentials directly ass...

متن کامل

Evidence-based guideline update: intraoperative spinal monitoring with somatosensory and transcranial electrical motor evoked potentials: report of the Therapeutics and Technology Assessment Subcommittee of the American Academy of Neurology and the American Clinical Neurophysiology Society.

OBJECTIVE To evaluate whether spinal cord intraoperative monitoring (IOM) with somatosensory and transcranial electrical motor evoked potentials (EPs) predicts adverse surgical outcomes. METHODS A panel of experts reviewed the results of a comprehensive literature search and identified published studies relevant to the clinical question. These studies were classified according to the evidence...

متن کامل

Monitoring of Motor and Somatosensory Evoked Potentials During Spine Surgery: Intraoperative Changes and Postoperative Outcomes

OBJECTIVE To evaluate whether the combination of muscle motor evoked potentials (mMEPs) and somatosensory evoked potentials (SEPs) measured during spinal surgery can predict immediate and permanent postoperative motor deficits. METHODS mMEP and SEP was monitored in patients undergoing spinal surgery between November 2012 and July 2014. mMEPs were elicited by a train of transcranial electrical...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical neurophysiology : official publication of the American Electroencephalographic Society

دوره 29 1  شماره 

صفحات  -

تاریخ انتشار 2012