Influence of internal fixator stiffness on murine fracture healing: two types of fracture healing lead to two distinct cellular events and FGF-2 expressions.

نویسندگان

  • Masaki Ueno
  • Ken Urabe
  • Kouji Naruse
  • Kentaroo Uchida
  • Hiroaki Minehara
  • Takeaki Yamamoto
  • Roland Steck
  • Laura Gregory
  • Martin E Wullschleger
  • Michael A Schuetz
  • Moritoshi Itoman
چکیده

This study aimed to clarify the relationship between the mechanical environment at the fracture site and endogenous fibroblast growth factor-2 (FGF-2). We compared two types of fracture healing with different callus formations and cellular events using MouseFix(TM) plate fixation systems for murine fracture models. Left femoral fractures were induced in 72 ten-week-old mice and then fixed with a flexible (Group F) or rigid (Group R) Mouse Fix(TM) plate. Mice were sacrificed on days 3, 5, 7, 10, 14, and 21. The callus volumes were measured by 3D micro-CT and tissues were histologically stained with hematoxylin & eosin or safranin-O. Sections from days 3, 5, and 7 were immunostained for FGF-2 and Proliferating Cell Nuclear Antigen (PCNA). The callus in Group F was significantly larger than that in Group R. The rigid plate allowed bone union without a marked external callus or chondrogenesis. The flexible plate formed a large external callus as a result of endochondral ossification. Fibroblastic cells in the granulation tissue on days 5 and 7 in Group F showed marked FGF-2 expression compared with Group R. Fibroblastic cells showed ongoing proliferation in granulation tissue in group F, as indicated by PCNA expression, which explained the relative granulation tissue increase in group F. There were major differences in early phase endogenous FGF-2 expression between these two fracture healing processes, due to different mechanical environments.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Combined Use of Percutaneous Canulated Screws and External or Internal Fixationfor Less Invasive Treatment of Tibial Plateaux Fractures

The classic way of treatment of tibial plateau fractures with an extensive approach, opening of the knee and compressive internal fixation can lead to major complications such as infection, skin necrosis and knee stiffness. Here we present a less invasive and thus safer surgical technique, and its indications and results. Twenty patients with various types of fractures according to Schatzker’s ...

متن کامل

Experimental and numerical investigation into the influence of loading conditions in biomechanical testing of locking plate fracture fixation devices

OBJECTIVES Secondary fracture healing is strongly influenced by the stiffness of the bone-fixator system. Biomechanical tests are extensively used to investigate stiffness and strength of fixation devices. The stiffness values reported in the literature for locked plating, however, vary by three orders of magnitude. The aim of this study was to examine the influence that the method of restraint...

متن کامل

Study on the application of external fixator and limited internal fixation in combined treatment of limbs fractures

Objective: This study aims to investigate the application of external fixator and limited internal fixation in combined treatment of limbs fractures. Methods: From September 14th, 2015 to September 14th, 2016, a total number of 100 limbs fractured patients were collected in our hospital. They were randomly divided into two groups (the observation group and the control group) with 50 patients in...

متن کامل

Simulation and Optimization of Fracture Healing

The objective of this paper is to present an optimization algorithm for the optimization of the axial stiffness of a fixator used in fracture healing. To this end, numerical simulations of fracture healing with 2D and 3D models are used. The simulation is extended by a tool to observe the bridging of two bone fragments, called bridge detector. Using this bridge detector, the optimization criter...

متن کامل

Assay of Tgf-β And B-Fgf on the Potential of Peripheral Blood-Borne Stem Cells and Bone Marrow-Derived Stem Cells in Wound Healing in a Murine Model

Purpose: Effects of TGF-b and b-FGF on the Potential of Peripheral Blood-Borne Stem Cells and Bone Marrow-Derived Stem Cells In Wound Healing in a Murine Model.Materials and Methods: Peripheral blood mesenchymal stem cells (PBMSCs) and bone marrow stem cells (BMSCs) cultured in media with transforming growth factor-beta (TGF-b) and basic fibroblast growth factor (b-FGF). Stem cells labeled with...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Experimental animals

دوره 60 1  شماره 

صفحات  -

تاریخ انتشار 2011