Anaphylactoid reactions due to haemodialysis, haemofiltration, or membrane plasma separation.
نویسندگان
چکیده
A previously undescribed anaphylactoid reaction to haemodialysis, haemofiltration, or membrane plasma separation occurred in 15 patients receiving regular dialysis. The illness varied in severity from urticaria, sneezing, and watering of the eyes to severe bronchospasm and cardiovascular collapse, and began within a minute of blood being returned from the dialyser or filtration device to the patient. Reactions developed only when a dialyser sterilised with ethylene oxide was used for the first time and never after sterilisation with formalin. Several patients had more than one reaction while three had a reaction each time a new dialyser was used. Incorrect priming of the dialysers may be a partial explanation of these attacks, but the exact reason for their occurrence is unknown. This is a dramatic and potentially life-threatening syndrome that may not previously have been recognised as a reaction to dialysis.
منابع مشابه
New insights in dialysis membrane biocompatibility: relevance of adsorption properties and heparin binding.
In the last 10 years, the concept of biocompatibility as applied to haemodialysis membranes has gained a general clinical acceptance in light of the knowledge that the clinical expression of b2-microglobulin (b2m) amyloidosis found in long-term haemodialyzed patients was governed by the characteristics of dialysis membranes. Highly permeable and biocompatible synthetic membranes interfere with ...
متن کاملProteinuria in the transplanted patient.
icity versus cytoprotection—how, why, when and where? Nitric and/or modulating factors are involved, though perOxide: Biology and Chemistry 1997; 1: 107–120 haps only in a minority of cases. 6. Amore A, Cirina P, Peruzzi L, Gianoglio B, Coppo R. Acetate The simple procedure of rinsing with sodium bicarintolerance is mediated by enhanced synthesis of nitric oxide by bonate—containing solutions m...
متن کاملChronic intermittent haemofiltration and haemodialysis in end stage chronic heart failure with oedema refractory to high dose frusemide.
OBJECTIVE To assess the benefits and problems of chronic intermittent treatment with haemofiltration or haemodialysis or both in patients with severe chronic heart failure (New York Heart Association class III or IV) and oedema refractory to pharmacological treatment. DESIGN AND SETTING A retrospective case-cohort study. A general hospital in The Netherlands. PATIENTS The results of chronic...
متن کاملKinin generation by hemodialysis membranes as a possible cause of anaphylactoid reactions.
1. Severe anaphylactoid reactions have been reported in some patients treated with angiotensin converting enzyme (ACE) inhibitors during hemodialysis with a polyacrylonitrile (PAN) membrane. Generation of bradykinin via contact activation at the negatively charged membrane surface and reduced bradykinin breakdown due to ACE inhibition have been suggested as possible causes. This hypothesis was ...
متن کاملTailoring high-cut-off membranes and feasible application in sepsis-associated acute renal failure: in vitro studies.
BACKGROUND As removal of pro-inflammatory cytokines is limited in conventional diffusive or convective extracorporeal therapies, we studied in two polysulphone membranes with an industrial albumin sieving coefficient of 0.05 (Type A) and 0.13 (Type B) cytokine (IL-6, IL-8, IL-1beta, IL-1ra, TNF-alpha) and plasma protein (albumin, cystatin C, total proteins) permeability profiles. Based on the c...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- British medical journal
دوره 285 6355 شماره
صفحات -
تاریخ انتشار 1982