Measurement of real-time tissue elastography in a phantom model and comparison with transient elastography in pediatric patients with liver diseases.

نویسندگان

  • Jens-Peter Schenk
  • Gerhard Alzen
  • Volker Klingmüller
  • Ulrike Teufel
  • Saroa El Sakka
  • Guido Engelmann
  • Buket Selmi
چکیده

PURPOSE We aimed to determine the comparability of real-time tissue elastography (RTE) and transient elastography (TE) in pediatric patients with liver diseases. MATERIALS AND METHODS RTE was performed on the Elasticity QA Phantom Model 049 (Computerized Imaging Reference Systems Company Inc., Norfolk, Virginia, USA), which has five areas with different levels of stiffness. RTE measurements of relative stiffness (MEAN [mean value of tissue elasticity], AREA [% of blue color-coded stiffer tissue]) in the phantom were compared with the phantom stiffness specified in kPa (measurement unit of TE). RTE and TE were performed on 147 pediatric patients with various liver diseases. A total of 109 measurements were valid. The participants had following diseases: metabolic liver disease (n=25), cystic fibrosis (n=20), hepatopathy of unknown origin (n=11), autoimmune hepatitis (n=12), Wilson's disease (n=11), and various liver parenchyma alterations (n=30). Correlations between RTE and TE measurements in the patients were calculated. In addition, RTE was performed on a control group (n=30), and the RTE values between the patient and control groups were compared. RESULTS The RTE parameters showed good correlation in the phantom model with phantom stiffness (MEAN/kPa, r=-0.97; AREA/kPa, r=0.98). However, the correlation of RTE and TE was weak in the patient group (MEAN/kPa, r=-0.23; AREA/kPa, r=0.24). A significant difference was observed between the patient and control groups (MEAN, P = 5.32 e-7; AREA, P = 1.62 e-6). CONCLUSION In the phantom model, RTE was correlated with kPa, confirming the presumed comparability of the methods. However, there was no direct correlation between RTE and TE in patients with defined liver diseases under real clinical conditions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of transient elastography (FibroScan) for diagnosis of fibrosis in non-alcoholic fatty liver disease: A systematic review and meta-analysis

Background: Transient elastography (TE) is a new modality for the diagnosis of liver fibrosis caused by various etiologies. This study was conducted to determine the accuracy of TE in detecting the different stages of liver fibrosis in non-alcoholic fatty liver disease (NAFLD) patients. Methods: MEDLINE/PubMed, Embase, Ovid, Cochrane Library, American College of Physicians (ACP) Journal Club...

متن کامل

Assessment of hepatic fibrosis by transient elastography in rheumatoid arthritis patients receiving methotrexate

Background and Aim: Methotrexate (MTX) is commonly used in the treatment of diseases such as rheumatoid arthritis (RA) but, its hepatotoxicity potential, always has been a major concern. The aim of this study is to determine the rate of liver fibrosis by transient elastography (TE) method and its relationship with cumulative dose of MTX and duration of treatment, in rheumatoid arthritis patient...

متن کامل

Investigation of Shape Functions Role on the Mesh-free Method Application in Soft Tissue Elastography

In current study, The Mesh-free method based on weak-form formulation coupled with the ultrasound imaging technique is developed. This problem consists in computing the deformation of an elastic non-homogenous phantom by numerical methods (both Mesh-free and Finite Element) and converge their results to the measured deformation by the ultrasound. The shape functions of Mesh-free are approximate...

متن کامل

An ultrasound transient elastography system with coded excitation

BACKGROUND Ultrasound transient elastography technology has found its place in elastography because it is safe and easy to operate. However, it's application in deep tissue is limited. The aim of this study is to design an ultrasound transient elastography system with coded excitation to obtain greater detection depth. METHODS The ultrasound transient elastography system requires tissue vibra...

متن کامل

Increased liver stiffness measurement values using transient elastography in Egyptian patients with acute viral hepatitis

Transient elastography (TE) is one of the most widely used noninvasive techniques for the assessment of the stage of liver fibrosis. This technique is a rapid, painless, non-invasive, reproducible, can be used in different liver diseases, it takes information from a much larger portion of the tissue in comparison with liver biopsy. Increased liver stiffness (LS) is not always diagnostic of fibr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Diagnostic and interventional radiology

دوره 20 1  شماره 

صفحات  -

تاریخ انتشار 2014