The Kora Pacemaker is Safe and Effective for Magnetic Resonance Imaging
نویسندگان
چکیده
BACKGROUND The impact of magnetic resonance imaging (MRI) on pacemakers is potentially hazardous. We present clinical results from a novel MRI conditional pacing system with the capability to switch automatically to asynchronous mode in the presence of a strong magnetic field. AIMS The IKONE (Assessment of the MRI solution: KORA 100™ and Beflex™ pacing leads system) study is an open-label, prospective, multicenter study aimed at confirming the safety and effectiveness of the system, when used in patients undergoing MRI of anatomical regions excluding the chest. METHODS Primary eligibility criteria included patients implanted with the system, with or without a clinically indicated MRI. The primary endpoint was to confirm no significant change in pacing capture thresholds at 1 month after an MRI, with an absolute difference of ≤0.75 V between the pre- and 1-month post-MRI for both atrial and ventricular capture thresholds. RESULTS Out of 33 patients enrolled (mean age: 72.8 ± 11.4 years, 70% male, implant indication or device), 29 patients implanted with the MRI conditional system underwent an MRI 6-8 week postimplant. The study reached its primary endpoint: the mean absolute difference in pacing capture threshold at 1-month post-MRI versus pre-MRI was less than 0.75 V in the atrium (Δ = 0.18 ± 0.16 V, P-value < 0.001) and in the ventricle (Δ = 0.18 ± 0.22 V, P-value < 0.001). There were no adverse events related to the MRI procedure nor were there reports of patient symptoms or discomfort associated. MR image quality was of diagnostic quality in all patients. CONCLUSION Lead electrical performance as measured by difference in capture thresholds were not impacted by MRI. This first clinical evaluation of a novel MRI conditional system demonstrates it is safe and effective for use in out-of-chest, 1.5-T MR imaging.
منابع مشابه
Application of Magnetic Resonance Imaging (MRI) as a safe & Application of Magnetic Resonance Imaging (MRI) as a safe & non-destructive method for monitoring of fruit & vegetable in postharvest period
To investigate and control quality, one must be able to measure quality-related attributes. Quality of produce encompasses sensory attributes, nutritive values, chemical constituents, mechanical properties, functional properties and defects. MRI has great potential for evaluating the quality of fruits and vegetables. The equipment now available is not feasible for routine quality testing. The ...
متن کاملCardiac and Hepatic T2*-Weighted Magnetic Resonance Imaging
Abstract Background Iron overload is the main transfusion related side effects in patients with transfusion dependent hemoglobinopathies. Severe iron deposition in tissues leads to organ dysfunction. Many organs can be affected such as heart, liver, and endocrine organs. Cardiac failure and liver fibrosis are the consequent of Iron overload in transfusion dependent hemoglobinopathy. Magne...
متن کاملStatic Coil Design Considerations for the Magnetic Resonance Imaging
One of the main challenges in developing magnetic resonance imaging (MRI) systems is to create a static coil that needs to generate magnetic field density along with the characteristics of optimal homogeneity and magnitude size. To do this, two N42 Block PMs are used and the iron core is designed and optimized in accordance with the dimensions of PM pieces using ANSYS Maxwell software. Then, al...
متن کاملDynamic Contrast Magnetic Resonance Imaging (DCE-MRI) and Diffusion Weighted MR Imaging (DWI) for Differentiation between Benign and Malignant Salivary Gland Tumors
Background: Salivary gland tumors form nearly 3% of head and neck tumors. Due to their large histological variety and vicinity to facial nerves, pre-operative diagnosis and differentiation of benign and malignant parotid tumors are a major challenge for radiologists. Objective: The majority of these tumors are benign; however, sometimes they tend to transform into a malignant form. Functional M...
متن کاملThe Optimization of Magnetic Resonance Imaging Pulse Sequences in Order to Better Detection of Multiple Sclerosis Plaques
Background and objective: Magnetic resonance imaging (MRI) is the most sensitive technique to detect multiple sclerosis (MS) plaques in central nervous system. In some cases, the patients who were suspected to MS, Whereas MRI images are normal, but whether patients don’t have MS plaques or MRI images are not enough optimized enough in order to show MS plaques? The aim of the current study is ...
متن کامل