Are the dynamic response characteristics of brachial artery flow-mediated dilation sensitive to the magnitude of increase in shear stimulus?

نویسندگان

  • K E Pyke
  • J A Hartnett
  • M E Tschakovsky
چکیده

The purpose of this study was to determine the dynamic characteristics of brachial artery dilation in response to step increases in shear stress [flow-mediated dilation (FMD)]. Brachial artery diameter (BAD) and mean blood velocity (MBV) (Doppler ultrasound) were obtained in 15 healthy subjects. Step increases in MBV at two shear stimulus magnitudes were investigated: large (L; maximal MBV attainable), and small (S; MBV at 50% of the large step). Increase in shear rate (estimate of shear stress: MBV/BAD) was 76.8 +/- 15.6 s(-1) for L and 41.4 +/- 8.7 s(-1) for S. The peak %FMD was 14.5 +/- 3.8% for L and 5.7 +/- 2.1% for S (P < 0.001). Both the L (all subjects) and the S step trials (12 of 15 subjects) elicited a biphasic diameter response with a fast initial phase (phase I) followed by a slower final phase. Relative contribution of phase I to total FMD when two phases occurred was not sensitive to shear rate magnitude (r(2) = 0.003, slope P = 0.775). Parameters quantifying the dynamics of the FMD response [time delay (TD), time constant (tau)] were also not sensitive to shear rate magnitude for both phases (phase I: TD r(2) = 0.03, slope P = 0.376, tau r(2) = 0.04, slope P = 0.261; final phase: TD r(2) = 0.07, slope P = 0.169, tau r(2) = 0.07, slope P = 0.996). These data support the existence of two distinct mechanisms, or sets of mechanisms, in the human conduit artery FMD response that are proportionally sensitive to shear stimulus magnitude and whose dynamic response is not sensitive to shear stimulus magnitude.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Local Shear Stress and Brachial Artery Flow–Mediated Dilation

Endothelium-dependent flow-mediated dilation is a homeostatic response to short-term increases in local shear stress. Flow-mediated dilation of the brachial artery in response to postischemic reactive hyperemia is impaired in patients with cardiovascular disease risk factors and may reflect local endothelial dysfunction in the brachial artery. However, previous studies have largely neglected th...

متن کامل

Impact of shear stimulus, risk factor burden and early atherosclerosis on the time-course of brachial artery flow-mediated vasodilation.

OBJECTIVES Our aim was to analyze flow-mediated dilation (FMD) time-course in response to forearm occlusion in the clinical setting. METHODS AND RESULTS In 50 asymptomatic subjects, monitoring software measuring continuous beat-to-beat change in brachial artery diameter was used to determine FMD magnitude in percentage change in peak diameter from baseline (FMD-DeltaD), time to peak diameter ...

متن کامل

Local shear stress and brachial artery flow-mediated dilation: the Framingham Heart Study.

Endothelium-dependent flow-mediated dilation is a homeostatic response to short-term increases in local shear stress. Flow-mediated dilation of the brachial artery in response to postischemic reactive hyperemia is impaired in patients with cardiovascular disease risk factors and may reflect local endothelial dysfunction in the brachial artery. However, previous studies have largely neglected th...

متن کامل

Blood Vessels Impact of Shear Rate Modulation on Vascular Function in Humans

Shear stress is an important stimulus to arterial adaptation in response to exercise and training in humans. We recently observed significant reverse arterial flow and shear during exercise and different antegrade/retrograde patterns of shear and flow in response to different types of exercise. The purpose of this study was to simultaneously examine flow-mediated dilation, a largely NO-mediated...

متن کامل

Brachial artery flow-mediated dilation during handgrip exercise: evidence for endothelial transduction of the mean shear stimulus.

Exercise elevates shear stress in the supplying conduit artery. Although this is the most relevant physiological stimulus for flow-mediated dilation (FMD), the fluctuating pattern of shear that occurs may influence the shear stress-FMD stimulus response relationship. This study tested the hypothesis that the brachial artery FMD response to a step increase in shear is influenced by the fluctuati...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of applied physiology

دوره 105 1  شماره 

صفحات  -

تاریخ انتشار 2008