Automatic gradient preemphasis adjustment: a 15-minute journey to improved diffusion-weighted echo-planar imaging.
نویسندگان
چکیده
Image distortion caused by gradient eddy currents is a major problem in the use of diffusion tensor imaging (DTI), as using the uncorrected images for calculation of apparent diffusion coefficient (ADC) and diffusion anisotropy will result in areas of artificially increased anisotropy and ADC at the edge of the images, as well as decreased spatial resolution and accuracy in ADC computations overall. This distortion may be substantially reduced by careful adjustment of the gradient preemphasis unit. A completely automatic method of adjusting the preemphasis unit is proposed which finds the optimal settings for all three gradient directions in approximately 15 min by estimating the magnitudes of the eddy currents at various delay times after a test gradient. The pixel shifts in a 64 x 128 echo-planar diffusion-weighted image with a diffusion gradient strength of 30 mT/m were reduced to less than 0.2.
منابع مشابه
Gradient preemphasis calibration in diffusion-weighted echo-planar imaging.
This article describes a method which enables fast and objective pulse-sequence-specific preemphasis calibration, using standard pulse sequences and system hardware. The method is based on a k-space measurement technique, and has been applied to single-shot, diffusion-weighted, spin-echo, echo-planar imaging (DW-SE-EPI), which is particularly sensitive to eddy-current-induced image distortions....
متن کاملCorrecting High Order Eddy Current Induced Distortion for Diffusion Weighted Echo Planar Imaging
INTRODUCTION It is well known that diffusion weighted echo planar imaging (DW-EPI) often suffers from direction dependent distortions due to diffusion gradient generated eddy currents. These distortions, if not corrected, can lead to misregistration among DW images of different directions and inaccuracies in any post processing operations involving DW image combination. Dual spin echo DW-EPI [1...
متن کاملDouble-spin-echo diffusion weighting with a modified eddy current adjustment.
Magnetic field inhomogeneities like eddy current-related gradient fields cause geometric distortions in echo-planar imaging (EPI). This in particular affects diffusion-weighted imaging where these distortions vary with the direction of the diffusion weighting and hamper the accurate determination of diffusion parameters. The double-spin-echo preparation often used aims to reduce the cumulative ...
متن کاملPrevention of motion-induced signal loss in diffusion-weighted echo-planar imaging by dynamic restoration of gradient moments.
PURPOSE Head motion is a significant problem in diffusion-weighted imaging as it may cause signal attenuation due to residual dephasing during strong diffusion encoding gradients even in single-shot acquisitions. Here, we present a new real-time method to prevent motion-induced signal loss in DWI of the brain. METHODS The method requires a fast motion tracking system (optical in the current i...
متن کاملElimination of eddy current artifacts in diffusion-weighted echo-planar images: the use of bipolar gradients.
Small gradient fields resulting from incompletely canceled eddy currents can cause geometric distortion in echo-planar images. Although this distortion is negligible in most echoplanar applications, the large gradient pulses used in diffusion-weighted echo-planar imaging can result in significant image distortion. In this report, it is shown that this distortion can be significantly reduced by ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Magnetic resonance in medicine
دوره 47 1 شماره
صفحات -
تاریخ انتشار 2002