Interchangeability of pencil-beam and fan-beam dual-energy X-ray absorptiometry measurements in piglets and infants.

نویسندگان

  • Winston W K Koo
  • Mouhanad Hammami
  • Elaine M Hockman
چکیده

BACKGROUND Compared with the older pencil-beam (PB) dual-energy X-ray absorptiometry (DXA), the newer fan-beam (FB) DXA has the advantage of faster scan acquisition and greater accuracy of body-composition measurement in small subjects. However, no data exist on the relation between the measurements obtained with these techniques. OBJECTIVE The objective of the study was to investigate whether PB and FB DXA measurements in small subjects are interchangeable. DESIGN PB and FB DXA scans were performed on 26 piglets and 54 infants to examine the relation between the measurements obtained by using the 2 techniques. RESULTS The correlation between all PB and FB DXA measurements of variables (total weight, bone area, bone mineral content, bone mineral density, and lean and fat masses) approached 1.0, but there were significant differences in absolute values. The extent of the differences varied according to the variable, with the lowest value for total weight (mean difference: approximately 1% for both piglets and infants) and the highest value for bone mineral content (mean difference: 35.3% and 36.7% for piglets and infants, respectively). PB and FB DXA measurements were strongly predictive of each other after adjustment (r(2) = 0.927-1.000 for the piglet data and 0.939-0.999 for the infant data). CONCLUSION In small subjects, DXA measurements from PB and FB techniques were strongly predictive of each other, although their absolute values differed. Thus, group comparison of PB and FB DXA data is possible after adjustment of the data from either technique. It is advisable to generate normative data for each technique and to use the same technique throughout longitudinal studies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Bone Mineral Density Measured by Dual X-ray, Axial Dual-energy Photon X-ray Absorptiometry and Laser Absorptiometry of Calcaneus

The objective of this study was to validate the use of bone mineral measurements of the calcaneus bone by dual X-ray and laser (DXL) in a cross-sectional study carried out in an osteoporosis clinic. Measurements of bone mineral density (BMD) at proximal femur and spine were obtained by dual-energy photon X-ray absorptiometry (DEXA). Osteoporosis was defined by a DEXA T-score <-2.5 at the femora...

متن کامل

Cross-calibration of pencil-beam (DPX-NT) and fan-beam (QDR-4500C) dual-energy X-ray absorptiometry for sarcopenia

Sarcopenia, defined as the loss of muscle mass accompanied by weakness, is an important factor leading to frailty and is a growing concern in the aging Japanese society. Muscle mass can be calculated by dual-energy X-ray absorptiometry (DXA), but results differ between devices produced by different manufactures. Thus, cross-calibration is needed to compare body composition results in multicente...

متن کامل

Validation of fan beam dual energy x ray absorptiometry for body composition assessment in adults aged 18-45 years.

BACKGROUND Pencil beam dual energy x ray absorptiometry (DXA) has been shown to provide valid estimates of body fat (%BF), but DXA fan beam technology has not been adequately tested to determine its validity. OBJECTIVE To compare %BF estimated from fan beam DXA with %BF determined using two and three compartment (2C, 3C) models. METHODS Men (n = 25) and women (n = 31), aged 18-41 years, par...

متن کامل

A review of emerging trends in dual-energy X-ray absorptiometry (DXA)

New fan-beam DXA systems can detect vertebral fractures with fast, low-dose lateral scans of the vertebra from T4 to L4 in as little as 10 seconds. Vertebral fractures are the most common fracture in osteoporosis and an indication for treatment irrespective of Bone Mineral Density [1-3]. However, without a diagnostic test such as that available on fan-beam DXA systems, as many as 75% of vertebr...

متن کامل

Measurement of fat mass using DEXA: a validation study in elderly adults.

The accuracy of total body fat mass and leg fat mass measurements by fan-beam dual-energy X-ray absorptiometry (DEXA) was assessed in 60 healthy elderly subjects (aged 70-79 yr). Total fat and leg fat mass at four leg regions (total leg, thigh, midthigh, and calf) were measured with the QDR 4500A (Hologic, Waltham, MA). The four-compartment model and multislice computed tomography scans were se...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The American journal of clinical nutrition

دوره 78 2  شماره 

صفحات  -

تاریخ انتشار 2003