Innovations in 27 - Gauge Vitrectomy for Sutureless Microincision

نویسندگان

  • Fernando Arevalo
  • Masahito Ohji
چکیده

T he common thinking regarding surgical wounds is that “much smaller is much better.” Based on this concept, microincision vitrectomy surgery (MIVS) with 25or 23-gauge instruments has taken over from conventional 20-gauge vitrectomy in many cases, and the technology has evolved radically during the past several years. Along with the development of ergonomic instrumentation and new-generation vitrectomy machines, there has been a rapid adoption of smaller gauge instrumentation on a global scale over the past several years (Figure 1). The above-mentioned trends and future perspectives in modern MIVS led us to initiate a 27-gauge vitrectomy project in 2007. Development of a 27-gauge chandelier illumination fiber was the first step.1 After years of strenuous efforts, DORC was the first company to offer a complete 27-gauge vitrectomy system. The preliminary surgical results using the first-generation 27-gauge vitrectomy system to treat vitreoretinal diseases were reported in 2010.2 At that time, the system was used only in select cases— mainly macular disease and simple vitreous hemorrhage— similar to the situation in the early days of 25-gauge vitrectomy. Nevertheless, both the anatomical and visual results were very promising. The most remarkable findings were that there was no need to transition to a larger gauge, no suturing was required, and no hypotony was observed in any of the study cases. To explore the potential for more widespread use of this ultrasmall-gauge system, its functionalities must be upgraded to treat more challenging conditions, such as cases of advanced proliferative diabetic retinopathy and primary rhegmatogenous retinal detachment. The most critical aspect of 27-gauge vitrectomy that must be improved is the cutting efficiency of vitreous cutter. According to the Hagen-Poiseuille law (Figure 2), the flow volume of fluid through a pipe can be increased by increasing the pressure differences between the ends of the pipe and/or by decreasing the coefficient of viscosity. This suggests that the cutting efficiency (vitreous flow) of the 27-gauge vitreous cutter can be improved by (1) reducing the bite size at higher cut rates to decrease the flow viscosity (resistance) and/or (2) maintaining a longer opening time of the cutting port with a maximum aspiration pressure. In this article, we describe 2 recently introduced technologies that may help surgeons realize ultrahigh performance with 27-gauge vitrectomy probes. Innovations in 27-Gauge Vitrectomy for Sutureless Microincision Vitrectomy Surgery

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Perioperative changes of the intraocular pressure during the treatment of epiretinal membrane by using 25- or 27-gauge sutureless vitrectomy without gas tamponade

PURPOSE The purpose of this study was to compare perioperative intraocular pressures (IOPs) in 25- or 27-gauge microincision vitrectomy surgery (MIVS) and to evaluate the stability of postoperative sclerotomy closure. MATERIALS AND METHODS This is a retrospective review of 147 eyes treated for epiretinal membrane by using 25- or 27-gauge MIVS as the initial vitrectomy (25-gauge phacovitrectom...

متن کامل

Comparison of Surgically-induced Astigmatism after Combined Phacoemulsification and 23-Gauge Vitrectomy: 2.2-mm vs. 2.75-mm Cataract Surgery

PURPOSE The 2.2-mm microincision cataract surgery and small-gauge vitrectomy system is known to result in less surgically-induced astigmatism (SIA) in comparison to conventional surgical methods. We compared the amounts of SIA after combined phacoemulsification and 23-gauge transconjunctival sutureless vitrectomy (23G-TSV) using the 2.2-mm microincision and 2.75-mm standard incision methods. ...

متن کامل

Review of Small Gauge Vitrectomy: Progress and Innovations

Purpose. To summarise the surgical advances and evolution of small gauge vitrectomy and discuss its principles and application in modern vitreoretinal surgery. The advent of microincisional vitrectomy systems (MIVS) has created a paradigm shift away from twenty-gauge vitrectomy systems, which have been the gold standard in the surgical management of vitreoretinal diseases for over thirty years....

متن کامل

Micro Incision Vitrectomy Surgery (MIVS): An Overview

Introduction In today’s world of nano-technology where bigger no longer means better, everything from smartphones to surgical incisions are getting smaller and more refined. The advantages of smaller surgical incision have resulted in faster postoperative recovery. Vitreoretinal surgery is no exception. We have come a long way since the time of open sky vitrectomy and Machemer’s first 17-gauge ...

متن کامل

Outcomes of transconjunctival sutureless 27-gauge micro-incision vitrectomy surgery in diabetic vitreous haemorrhage

OBJECTIVE To evaluate the visual outcomes of 27-gauge transconjunctival sutureless vitrectomy surgery and its complications in patients with diabetic vitreous hemorrhage. METHODS A quasi-experimental study was conducted where eighty seven eyes of 87 uncontrolled type II diabetes mellitus patients presenting with diabetic vitreous hemorrhage were selected to undergo 27-gauge transconjunctival ...

متن کامل