Evaluation of matrix-assisted laser desorption ionization-time of flight mass spectrometry for rapid identification of Beta-hemolytic streptococci.

نویسندگان

  • Abdessalam Cherkaoui
  • Stéphane Emonet
  • José Fernandez
  • Didier Schorderet
  • Jacques Schrenzel
چکیده

This study was undertaken to evaluate matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) for the rapid identification of beta-hemolytic streptococci. We compared Bruker Biotyper 2.0 with Vitek2 coupled to the agglutination test. MALDI-TOF MS analysis of 386 beta-hemolytic streptococcal isolates yielded high-confidence identification to the species level for all 386 isolates. The Vitek2 gave high-confidence identification to the species level for 88% of Streptococcus agalactiae isolates (n = 269/306), 92% of Streptococcus pyogenes isolates (n = 48/52), and 39% of isolates of Streptococcus dysgalactiae serogroups C and G (n = 11/28).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Rapid discrimination between strains of beta haemolytic streptococci by intact cell mass spectrometry.

BACKGROUND & OBJECTIVES Beta haemolytic streptococci belonging to Lancefield group A, B, C and G cause a wide spectrum of clinical diseases. Hence there is a need for rapid and accurate typing of these strains. The present study was undertaken to evaluate the use of intact cell matrix assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS) for rapid discrimination b...

متن کامل

Performance of the Vitek MS matrix-assisted laser desorption ionization time-of-flight mass spectrometry system for identification of Gram-positive cocci routinely isolated in clinical microbiology laboratories.

We evaluated the performance of the Vitek MS for identification of Gram-positive cocci routinely isolated in clinical microbiology laboratories. With a total of 424 well-characterized isolates, the results of the Vitek MS were compared to those of conventional methods and 16S rRNA gene sequencing. The Vitek MS correctly identified 97.9 % of the isolates tested to species level. The Vitek MS cor...

متن کامل

Pushing the Limits of MALDI-TOF Mass Spectrometry: Beyond Fungal Species Identification

Matrix assisted laser desorption ionization time of flight (MALDI-TOF) is a powerful analytical tool that has revolutionized microbial identification. Routinely used for bacterial identification, MALDI-TOF has recently been applied to both yeast and filamentous fungi, confirming its pivotal role in the rapid and reliable diagnosis of infections. Subspecies-level identification holds an importan...

متن کامل

Application of matrix-assisted laser desorption ionization-time of flight mass spectrometry for identification of the fastidious pediatric pathogens Aggregatibacter, Eikenella, Haemophilus, and Kingella.

The accuracy of matrix-assisted laser desorption-ionization time of flight mass spectrometry (MALDI-TOF MS) in the identification of Haemophilus, Aggregatibacter, Cardiobacterium, Eikenella, and Kingella (HACEK) species was compared to that of phenotypic methods (Remel RapID and Vitek 2). Overall, Vitek MS correctly identified more isolates, incorrectly identified fewer isolates, and failed to ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 49 8  شماره 

صفحات  -

تاریخ انتشار 2011