Pull-out strength of screws from polymethylmethacrylate cement.
نویسندگان
چکیده
We aimed to determine the optimal method of inserting a screw into polymethylmethacrylate (PMMA) cement to enhance fixation. We performed six groups of ten axial pull-out tests with two sizes of screw (3.5 and 4.5 mm AO cortical) and three methods of insertion. Screws were placed into 'fluid' PMMA, into 'solid' PMMA by drilling and tapping, or into 'curing' PMMA with quarter-revolution turns every 30 seconds until the PMMA had hardened. After full hardening, we measured the maximum load to failure for each screw-PMMA construct. We found no significant difference in the pull-out strengths between screw sizes or between screws placed in fluid or solid PMMA. Screws placed in curing PMMA were significantly weaker: the relative strengths of solid, fluid and curing groups were 100%, 97% and 71%, respectively. We recommend the use of either solid or fluid insertion according to the circumstances and the preference of the surgeon.
منابع مشابه
Restoration of pull-out strength of the failed pedicle screw: biomechanical comparison of calcium sulfate vs polymethylmethacrylate augmentation.
OBJECTIVE The aim of the present study was to compare calcium sulfate (CAS) and polymethylmethacrylate (PMMA) bone cements used for the augmentation of a failed pedicle screw with biomechanical pull-out strength (POS) testing. METHODS Thirty lumbar vertebrae were harvested from 6 calves and bone mineral densities (BMD) were measured. Primary polyaxial pedicle screws were randomly inserted and...
متن کاملSrovnávací analýza šroubů Socon CS a Socon v ošetření osteoporotických zlomenin torakolumbální páteře – biomechanická studie
PURPOSE OF THE STUDY To compare the anchorage strength of Socon CS cannulated pedicle screws (B. Braun, Aesculap) with that of Socon screws in human cadaver vertebrae, using pull-out strength testing. MATERIAL Twelve samples involving T12 to L3 vertebrae were prepared and a total of 20 pedicle screws, 10 Socon CS and 10 Socon screws, were inserted in them. All screws were 55 mm in length and 6 ...
متن کاملPull-out strength of cemented solid versus fenestrated pedicle screws in osteoporotic vertebrae
OBJECTIVES Cement augmentation of pedicle screws could be used to improve screw stability, especially in osteoporotic vertebrae. However, little is known concerning the influence of different screw types and amount of cement applied. Therefore, the aim of this biomechanical in vitro study was to evaluate the effect of cement augmentation on the screw pull-out force in osteoporotic vertebrae, co...
متن کاملCorrelation of pull-out strength of cement-augmented pedicle screws with CT-volumetric measurement of cement.
BACKGROUND Cement augmentation of pedicle screws increases fixation strength in an osteoporotic spine. This study was designed to determine the cement distribution and the correlation between the pull-out strength of the augmented screw and the cement volume within polyurethane (PU) foam. METHODS Twenty-eight cannulated pedicle screws (6×45 mm) (Peter Brehm, Erlangen, Germany) with four holes...
متن کاملFixation strength of PMMA-augmented pedicle screws after depth adjustment in a synthetic bone model of osteoporosis.
The purpose of this study was to determine the change of fixation strength after adjusting the height of polymethylmethacrylate (PMMA)-augmented pedicle screws.Cement-augmented cannulated pedicle screws with or without PMMA augmentation with a radial hole in the distal third of the screw thread were inserted into synthetic bone blocks used to model osteoporosis. Screws were left unchanged (in s...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of bone and joint surgery. British volume
دوره 76 2 شماره
صفحات -
تاریخ انتشار 1994