Changes in quantitative ultrasound parameters during HIFU application

نویسندگان

  • Goutam Ghoshal
  • Jeremy P. Kemmerer
  • Michael L. Oelze
چکیده

Quantitative ultrasound (QUS) is a novel imaging technique that is hypothesized to be capable of monitoring of High Intensity Focused Ultrasound (HIFU) treatment by quantifying tissue changes during exposure. Experiments were conducted on fresh liver samples from rats and lesions were formed using a HIFU system (1-MHz, f/1.2). A wire thermocouple was inserted into the sample to monitor temperature elevation. Backscattered time domain waveforms were recorded using a clinical imaging system (Ultrasonix, L14-5 linear array) during the HIFU application and backscatter coefficients were estimated using a reference phantom technique. Two parameters were estimated from the backscatter coefficient (effective scatterer diameter (ESD) and effective acoustic concentration (EAC)) and two parameters were estimated from the envelope statistics (k parameter and μ parameter) of the backscattered echoes. At the end of the exposure the ESD, EAC and k parameters changed in the treated region by 20%, 50% and 15% respectively, compared to the untreated region. Furthermore, changes in QUS parameters followed the shape of the temperature profile recorded by the thermocouple. These results suggest that QUS techniques could be used for noninvasive thermometry of HIFU.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Numerical Study for Optimizing Parameters of High-Intensity Focused Ultrasound-Induced Thermal Field during Liver Tumor Ablation: HIFU Simulator

Introduction High intensity focused ultrasound (HIFU) is considered a noninvasive and effective technique for tumor ablation. Frequency and acoustic power are the most effective parameters for temperature distribution and the extent of tissue damage. The aim of this study was to optimize the operating transducer parameters such as frequency and input power in order to acquire suitable temperatu...

متن کامل

Real-Time Detection Of Multiple Lesions During High Intensity Focused Ultrasound (HIFU) Treatments

This work describes the development of a non-invasive real-time technique to detect changes in tissue caused by the production of multiple lesions during a HIFU treatment sequence. It is based on estimation of relative changes in tissue properties derived from backscattered RF data, such as speed of sound, density, absorption coefficient, backscattering power, etc., as a function of HIFU exposu...

متن کامل

Transmural Ultrasound Imaging of Thermal Lesion and Action Potential Changes in Perfused Canine Cardiac Wedge Preparations by High Intensity Focused Ultrasound Ablation

Intra-procedural imaging is important for guiding cardiac arrhythmia ablation. It is difficult to obtain intra-procedural correlation of thermal lesion formation with action potential (AP) changes in the transmural plane during ablation. This study tested parametric ultrasound imaging for transmural imaging of lesion and AP changes in high intensity focused ultrasound (HIFU) ablation using coro...

متن کامل

Viscoelasticity Parameters of Hifu Ablated Canine Liver Tissues Ex Vivo

Background: The feasibility of using elasticity imaging techniques for high–intensity–focused–ultrasound (HIFU) ablation monitoring and assessment has been previously demonstrated both in vitro and in vivo (e.g. [1,2]). Nonetheless, effective use of these techniques requires quantitative assessment of the changes in the mechanical properties of the ablated tissue during the treatment process. T...

متن کامل

Estimating dynamic changes of tissue attenuation coefficient during high-intensity focused ultrasound treatment

BACKGROUND This study investigated the dynamic changes of tissue attenuation coefficients before, during, and after high-intensity focused ultrasound (HIFU) treatment at different total acoustic powers (TAP) in ex vivo porcine muscle tissue. It further assessed the reliability of employing changes in tissue attenuation coefficient parameters as potential indicators of tissue thermal damage. M...

متن کامل