Durability of implanted electrodes and leads in an upper-limb neuroprosthesis.

نویسندگان

  • Kevin L Kilgore
  • P Hunter Peckham
  • Michael W Keith
  • Fred W Montague
  • Ronald L Hart
  • Martha M Gazdik
  • Anne M Bryden
  • Scott A Snyder
  • Thomas G Stage
چکیده

Implanted neuroprosthetic systems have been successfully used to provide upper-limb function for over 16 years. A critical aspect of these implanted systems is the safety, stability, and-reliability of the stimulating electrodes and leads. These components are (1) the stimulating electrode itself, (2) the electrode lead, and (3) the lead-to-device connector. A failure in any of these components causes the direct loss of the capability to activate a muscle consistently, usually resulting in a decrement in the function provided by the neuroprosthesis. Our results indicate that the electrode, lead, and connector system are extremely durable. We analyzed 238 electrodes that have been implanted as part of an upper-limb neuroprosthesis. Each electrode had been implanted at least 3 years, with a maximum implantation time of over 16 years. Only three electrode-lead failures and one electrode infection occurred, for a survival rate of almost 99 percent. Electrode threshold measurements indicate that the electrode response is stable over time, with no evidence of electrode migration or continual encapsulation in any of the electrodes studied. These results have an impact on the design of implantable neuroprosthetic systems. The electrode-lead component of these systems should no longer be considered a weak technological link.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Durability of Implanted Electrodes and Leads

Implanted neuroprosthetic systems have been successfully utilized to provide upper extremity function for over 15 years. A critical aspect of these implanted systems is the safety, stability and reliability of the stimulus delivery components. These components are: 1) the stimulating electrode itself, 2) the electrode lead, and 3) the lead-to-device connector. A failure in any of these componen...

متن کامل

Clinical experience of functional electrical stimulation for restoration of tetraplegic hand function

There are some Functional Electrical Stimulation (FES) systems that restore upper limb functions in tetraplegia. Surface electrodes [1], percutaneous intramuscular electrodes [2] and totally implantable electrodes [3] are used for stimulation in these neuroprostheses. The FESMATE system, developed by the Sendai FES Projects in Japan, is a portable multi-channel FES system with percutaneous elec...

متن کامل

Wireless wearable controller for upper-limb neuroprosthesis.

The objective of this project was to develop a wireless, wearable joint angle transducer to enable proportional control of an upper-limb neuroprosthesis by wrist position. Implanted neuroprostheses use functional electrical stimulation to provide hand grasp to individuals with tetraplegia. Wrist position is advantageous for control because it augments the tenodesis grasp and can be implemented ...

متن کامل

Long-term stability of sensitivity to intracortical microstimulation of somatosensory cortex.

OBJECTIVE The dexterous manipulation of objects depends heavily on somatosensory signals from the limb. The development of anthropomorphic robotic arms and of algorithms to decode intended movements from neuronal signals has stimulated the need to restore somatosensation for use in upper-limb neuroprostheses. Without touch and proprioception, patients have difficulty controlling prosthetic limb...

متن کامل

Performance of a Surgically Implanted Neuroprosthesis for Standing and Transfers

The purpose of this study was to determine the clinical performance of a surgically implanted neuroprosthesis for exercise, standing and transfers in individuals with low cervical or thoracic spinal cord injury (SCI). Seven adults with long term SCI received the system, consisting of a CWRU/VA implanted receiver-stimulator (IRS-8), 8 epimysial or intramuscular electrodes and a wearable external...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of rehabilitation research and development

دوره 40 6  شماره 

صفحات  -

تاریخ انتشار 2003