Improved fracture detection using the mammographic film-screen combination

نویسندگان

  • Y Faridah
  • BJJ Abdullah
  • KH Ng
چکیده

AIM The single emulsion or single screen system is usually reserved for mammography since its use in general radiography is limited. The purpose of this study is to compare the mammographic film-screen combination (MFC) and the standard film-screen combination (SFC) in terms of fracture and soft tissue injuries detection. PATIENTS, METHODS AND MATERIALS: In this prospective study, 41 patients from Accident and Emergency suspected of having injury in the hands, wrists, ankles and feet regions were radiographed using both MFC and SFC. These were compared in terms of image quality, presence of fractures and soft tissue injuries. The two different film-screen combinations were also compared in terms of detection of bony fragments, film characteristics such as film speed, contrast and spatial resolution, dose and cost. RESULTS The MFC gives statistically better image quality compared to SFC. In 10% of patients, fractures were detected only in the MFC, which also detects tiny bone fragments that may not be resolved by the SFC. The spatial resolution of the MFC is greater than the SFC. The film speed and contrast of the MFC are lower than that of the SFC. The doses of MFC were higher compared to SFC. CONCLUSIONS The MFC detects fractures better compared with SFC. However, the entrance skin dose for the mammographic film-screen combination was about 35% to 55% higher than the standard film-screen combination.

منابع مشابه

A Comparison of the effectiveness of Mammographic Film-Screen and Standard Film-Screen in the Detection of Small Bone Fractures

The use of mammography film-screen is limited in general radiography. The purpose of this study was to compare the effectiveness of mammographic film-screen and standard film-screen systems in the detection of small bone fractures. Radiographs were taken from patients' extremities and neck areas using mammography film-screen and standard film-screen (n=57 each). Fourteen other radiographs were ...

متن کامل

A Comparison of the effectiveness of Mammographic Film-Screen and Standard Film-Screen in the Detection of Small Bone Fractures

The use of mammography film-screen is limited in general radiography. The purpose of this study was to compare the effectiveness of mammographic film-screen and standard film-screen systems in the detection of small bone fractures. Radiographs were taken from patients' extremities and neck areas using mammography film-screen and standard film-screen (n=57 each). Fourteen other radiographs were ...

متن کامل

Performance tests for mammographic film-screen combinations: use of absolute techniques.

PURPOSE A performance comparison of film-screen combination used in mammography was conducted using conventional and new techniques. MATERIALS AND METHODS The performance of 30 mammographic film-screen combinations was evaluated by sensitometry, and the total performance was determined using phantom measurements. Quantum detection and light emission efficiency of the screens were also measure...

متن کامل

Improvement of Breast Cancer Detection Using Non-subsampled Contourlet Transform and Super-Resolution Technique in Mammographic Images

Introduction Breast cancer is one of the most life-threatening conditions among women. Early detection of this disease is the only way to reduce the associated mortality rate. Mammography is a standard method for the early detection of breast cancer. Today, considering the importance of breast cancer detection, computer-aided detection techniques have been employed to increase the quality of ma...

متن کامل

Mammographic microcalcifications: detection with xerography, screen-film, and digitized film display.

Pulverized bone specks and aluminum oxide specks were measured by hand into sizes ranging from 0.2 mm to 1.0 mm and then arranged in clusters. These clusters were superimposed on a human breast tissue phantom, and xeromammograms and screen-film mammograms of the clusters were made. The screen-film mammograms were digitized using a high-resolution laser scanner and then displayed on cathode ray ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

متن کامل
عنوان ژورنال:

دوره 1  شماره 

صفحات  -

تاریخ انتشار 2005