Preparation of the femoral bone cavity in cementless stems: broaching versus compaction

نویسندگان

  • Mette H Hjorth
  • Maiken Stilling
  • Kjeld Søballe
  • Poul Torben Nielsen
  • Poul H Christensen
  • Søren Kold
چکیده

Background and purpose - Short-term experimental studies have confirmed that there is superior fixation of cementless implants inserted with compaction compared to broaching of the cancellous bone. Patients and methods - 1-stage, bilateral primary THA was performed in 28 patients between May 2001 and September 2007. The patients were randomized to femoral bone preparation with broaching on 1 side and compaction on the other side. 8 patients declined to attend the postoperative follow-up, leaving 20 patients (13 male) with a mean age of 58 (36-70) years for evaluation. The patients were followed with radiostereometric analysis (RSA) at baseline, at 6 and 12 weeks, and at 1, 2, and 5 years, and measurements of periprosthetic bone mineral density (BMD) at baseline and at 1, 2, and 5 years. The subjective part of the Harris hip score (HHS) and details of complications throughout the observation period were obtained at a mean interval of 6.3 (3.0-9.5) years after surgery. Results - Femoral stems in the compaction group had a higher degree of medio-lateral migration (0.21 mm, 95% CI: 0.03-0.40) than femoral stems in the broaching group at 5 years (p = 0.02). No other significant differences in translations or rotations were found between the 2 surgical techniques at 2 years (p > 0.4) and 5 years (p > 0.7) postoperatively. There were no individual stems with continuous migration. Periprosthetic BMD in the 7 Gruen zones was similar at 2 years and at 5 years. Intraoperative femoral fractures occurred in 2 of 20 compacted hips, but there were none in the 20 broached hips. The HHS and dislocations were similar in the 2 groups at 6.3 (3.0-9.5) years after surgery. Interpretation - Bone compaction as a surgical technique with the Bi-Metric stem did not show the superior outcomes expected compared to conventional broaching. Furthermore, 2 periprosthetic fractures occurred using the compaction technique, so we cannot recommend compaction for insertion of the cementless Bi-Metric stem.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Specific Femoral Short Stems and Conventional-Length Stems in Primary Cementless Total Hip Arthroplasty.

There are several reported disadvantages with conventional-length femoral stems in cementless total hip arthroplasty (THA). Therefore, various efforts have been made to develop a specific femoral short stem to improve physiologic bone remodeling at the femoral aspect of a cementless THA. However, there are potential disadvantages with specific femoral short stems, such as malalignment, inadvert...

متن کامل

Still no single gold standard for using cementless femoral stems routinely in total hip arthroplasty

BACKGROUND There is now a clear trend with increased usage of cementless femoral stems for all ages and most patients. As the number of total hip arthroplasties (THAs) performed annually continues to increase with expanding indications for THA and demands for improved quality of life, so will the prevalence of THA in the elderly and aging populations. This is worrisome as the risk of complicati...

متن کامل

The modern, hybrid total hip arthroplasty for primary osteoarthritis at the Hospital for Special Surgery.

We describe our technique and rationale using hybrid fixation for primary total hip arthroplasty (THA) at the Hospital for Special Surgery. Modern uncemented acetabular components have few screw holes, or no holes, polished inner surfaces, improved locking mechanisms, and maximised thickness and shell-liner conformity. Uncemented sockets can be combined with highly cross-linked polyethylene lin...

متن کامل

Comparative Study of Bipolar Hemiarthroplasty for Femur Neck Fractures Treated with Cemented versus Cementless Stem

PURPOSE To compare and analyze clinical and radiologic outcomes of cemented versus cementless bipolar hemiarthroplasty for treatment of femur neck fractures. MATERIALS AND METHODS A total of 180 patients aged 65 years and over older who underwent bipolar hemiarthroplasty for treatment of displaced femur neck fractures (Garden stage III, IV) from March 2009 to February 2014 were included in th...

متن کامل

Cementless Hip Arthroplasty in Southern Iran, Midterm Outcome and Comparison of Two Designs

Background: Cementless hip prosthesis was designed to provide biologic fixation, without the use of cement. The second generation components have shown more reliable bone ingrowths and survival rates. We are reporting a midterm result of two designs of cementless prosthesis in a unique culture with different social habits and expectations.Methods: 52 primary cementless total hip arthroplasty in...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 87  شماره 

صفحات  -

تاریخ انتشار 2016