3D quantification of wall shear stress and oscillatory index using finite-element interpolations in 4D flow MR data of the thoracic aorta

نویسندگان

  • Julio Andres Sotelo
  • Jesús Urbina
  • Cristian Tejos
  • Israel Valverde
  • Daniel Hurtado
  • Sergio Uribe
چکیده

3D quantification of wall shear stress and oscillatory index using finite-element interpolations in 4D flow MR data of the thoracic aorta. Julio Andres Sotelo, Jesús Urbina, Cristian Tejos, Israel Valverde, Daniel Hurtado, and Sergio Uribe Biomedical Imaging Center, Pontificia Universidad Catolica de Chile, Santiago, Santiago, Chile, Electrical Engineering, Pontificia Universidad Catolica de Chile, Santiago, Santiago, Chile, Biomedical Imaging Center, Pontificia Universidad Catolica de Chile, Santiago, Chile, Radiology, School of Medicine, Pontificia Universidad Catolica de Chile, Santiago, Chile, Electrical Engineering, Pontificia Universidad Catolica de Chile, Santiago, Chile, Pediatric Cardiology Unit, Hospital Virgen del Rocio, Sevilla, Spain, Division of Cardiovascular Physiology, Institute of Biomedicine Seville (IBIS), Hospital Universitario Virgen de Rocio/CSIC/University of Seville, Sevilla, Spain, Biomedical Engineering Group, Pontificia Universidad Catolica de Chile, Santiago, Chile, Structural Engineering, Pontificia Universidad Catolica de Chile, Santiago, Chile

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

3D quantification of wall shear stress using finite-element interpolations from 4D flow MR data in the Thoracic Aorta

Background Actual methods to quantify wall shear stress (WSS) are performed on reformatted 2D planes from 4D flow data sets. This approach has the inherit limitation that only a few planes are analyzed on specific locations of the aorta, even though the full 3D velocity field is usually available. Another problem with this approach is that the process of locating 2D planes manually is dependent...

متن کامل

3D quantification of hemodynamics parameters of pulmonary artery and aorta using finite-element interpolations in 4D flow MR data

Background Several hemodynamic parameters based from 3D cine PC-MRI have been proposed during the last years, including wall shear stress (WSS), oscillatory index (OSI), vorticity and helicity among others. Most of these parameters are quantified using 2D planes, and only few methods have exploited the advantage of using the 3D data. The disadvantage of using 2D planes is that it does not provi...

متن کامل

Quantification of wall shear stress using finite-element interpolations in multidimensional phase contrast MR data of the thoracic aorta

Background Different methods have been proposed to estimate Wall Shear Stress (WSS). Morgan and co-workers (J Thorac Cardiovasc Surg and Ann Biomed Eng 1998) used a finite difference scheme to quantify the WSS tensor. However, it is well known that finite-difference methods cannot effectively handle complex geometries, as those found in the cardiovascular system. To account for arbitrary cross-...

متن کامل

Reproducibility and inter-observer variability of velocity and 3D wall shear stress derived from 4D flow MRI in the healthy aorta

Background 4D flow MRI is a powerful tool to measure timeresolved three-directional blood flow in the pathological and healthy aorta. The 3D aortic velocity measured with 4D flow MRI allows for derivation of 3D wall shear stress (WSS), which is believed to be related to vessel wall remodeling and possibly an important biomarker for aortopathy. However, it is still unclear how variability of the...

متن کامل

Advanced Quantitative Flow and Wall Shear Stress Analysis at 3T: 2D Vs 3D Time-Resolved MR Velocity Mapping

Introduction: Time-resolved (CINE) phase contrast (PC) MRI permits the assessment of blood flow within entire 3D vascular structures [1, 2]. The resulting high-dimensional datasets (3 spatial dimensions, 3 velocity directions, and time) require new visualization and quantification methods to derive reliable clinical parameters. In this context, an advanced flow quantification tool was developed...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013