Evaluation of Breast Tumor Detectability With Two Dedicated, Compact Scintillation Cameras

نویسنده

  • D. P. McElroy
چکیده

As part of the development of dedicated scintillation cameras for breast imaging, we compared the performances of two dedicated cameras with a standard clinical camera (Siemens Orbiter). One dedicated camera was based on a single position-sensitive photomultiplier tube (PSPMT) coupled to a 6 cm by 6 cm by 6 mm NaI(Tl) crystal. The other (LumaGem) was based on multiple-PSPMTs coupled to a 2 mm 2 mm by 6 mm matrix of NaI(Tl) crystals. Spatial resolution was measured with all cameras as a function of depth. The ability of the cameras to image small superficial tumors was tested with a phantom consisting of six hot cylindrical tumors of height 3 mm and varying diameters against a warm background. The tumors were imaged at various depths within the background using tumor-to-background activity concentration ratios of 10 : 1 and 5 : 1. Tumor contrast and signal-tonoise ratio were measured in all cases for all cameras. The dedicated cameras show improved shallow depth of field spatial resolution, contrast, and signal-to-noise ratio relative to the clinical camera when imaging the breast tumor phantom. This, with the additional advantage of being able to position the cameras close to the region of interest, suggests that dedicated cameras will play a strong role in scintimammography and other shallow depth of field applications.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Performance of Dedicated, Compact Scintillation Cameras

As part of the development of dedicated scintillation cameras, we compared the performances of 2 dedicated cameras with a standard clinical camera (Siemens Orbiter). One dedicated camera was based on a single Position Sensitive Photomultiplier (PSPMT) coupled to a 6 cm by 6 cm by 6 mm NaI(T1) crystal and the other was based on multiplePSPMTs coupled to a 2 mm by 2 mm by 6 mm matrix of NaI(T1) c...

متن کامل

New approach for calibration of pixelated scintillation detectors of intraoperative gamma cameras

Introduction:SURGEOSIGHT is a dedicated intra-operative hand-held gamma camera designed and manufactured by our team to be used for lymphoscintigraphy. Although conventional gamma cameras are widely used, they lack the capability of the sentinel lymph node (SLN) imaging in the operation room. Like conventional gamma cameras it is necessary to calibrate SURGEOSIGHT for linearity...

متن کامل

Detector design issues for compact nuclear emission cameras dedicated to breast imaging

Certain gamma ray and positron emitting radiotracers have shown great promise for use in the detection, diagnosis and staging of breast cancer. Unfortunately, standard nuclear emission cameras (SPECT, PET) found in the clinic are not practical for breast imaging of these emissions due to inadequate spatial and energy resolutions and sensitivity, large and awkward size, and relatively high cost ...

متن کامل

PSPMT and Photodiode Designs of a Small Scintillation Camera for Imaging Malignant Breast Tumors

We are investigating the concept of utilizing a small gamma ray scintillation camera to help identify and localize malignant breast tumors after a suspicious finding in a mammogram. Excellent sensitivity and specificity for malignant breast tumors has been achieved using conventional nuclear medicine scintillation cameras with certain 99mTc labeled radiopharmaceuticals. However, because of the ...

متن کامل

Comparative evaluation of lesion detectability for 6 PET imaging platforms using a highly reproducible whole-body phantom with (22)Na lesions and localization ROC analysis.

UNLABELLED The lesion detectability performance of 6 PET imaging platforms has been compared using a highly reproducible whole-body phantom and localization receiver operating characteristic (LROC) analysis. METHODS A realistic whole-body phantom consisting of brain, thorax with lungs and liver, and pelvis with bladder was assembled and outfitted with 27 semipermanent (22)Na lesions of variou...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2001