Improvement of Sensor Sensitivity of Quartz Crystal Microbalance by Mechanical and Chemical Treatment∗

نویسندگان

  • Z. Raicheva
  • V. Georgieva
  • V. Gadjanova
  • L. Vergov
  • Y. Lazarov
چکیده

The influence of quartz plate roughening on the dynamic parameters of quartz resonators has been studied. For this aim AT-cut quartz plates with a diameter of 8 mm, after a standard technological cleaning, are subjected to treatment with abrasive of varying grain sizes: 3, 7, 14 and 20 μm. Piezoquartz resonators are fabricated on these plates with 4 mm Au electrodes. The alterations of resonators’ dynamic parameters are followed after mass loading with a sensitive magnetron sputtered WO3 layer, 200 nm thick. Quartz Crystal Microbalance (QCM) sorption properties are evaluated for 100 ppm NH3 concentration; the frequency shift from 20 to 120 Hz, are obtained when the grain sizes change from 3 to 20 μm. The measured average roughness by Atomic Force Microscopy (AFM) was 179 nm, 288 nm, 763 nm for 7 μm, 14 μm and 20 μm, respectively. The influence of the etching process of AT-cut quartz plates on the QCM parameters has been studied. Quartz wafers (100 μm thick, with a diameter of 8 mm), have been etched in [NH4]2 F2: H2O = 1:1 solution at temperature range from 70C to 90C. The influence of etch treatment on the quartz surface morphology has been estimated by AFM. Sorption properties of QCM-MoO3 are evaluated at NH3 concentrations in the interval from 100 ppm to 500 ppm. The increase of effective sorption surface, obtained by mechanical and chemical treatment, can be successfully used to realize high sensitive QCM-thin film structure. PACS codes: 07.07.-a

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Noise Measurement Setup for Quartz Crystal Microbalance

Quartz crystal microbalance (QCM) is a high sensitive chemical sensor which has found widespread spectrum of applications. There are several mechanisms that are related to fluctuation phenomena. Since the aim of our research is oriented to study the sensitivity and influence of different kind of noises on sensor resolution, we modified an existing method to measure the small frequency fluctuati...

متن کامل

Molecular Imprinting Technology in Quartz Crystal Microbalance (QCM) Sensors

Molecularly imprinted polymers (MIPs) as artificial antibodies have received considerable scientific attention in the past years in the field of (bio)sensors since they have unique features that distinguish them from natural antibodies such as robustness, multiple binding sites, low cost, facile preparation and high stability under extreme operation conditions (higher pH and temperature values,...

متن کامل

Ultrasensitive detection of thrombin using surface plasmon resonance and quartz crystal microbalance sensors by aptamer-based rolling circle amplification and nanoparticle signal enhancement.

The surface plasmon resonance (SPR) and quartz crystal microbalance (QCM) aptasensors combined with rolling circle amplification and bio-bar-coded AuNP enhancement have been applied to detect the human α-thrombin for the first time. The assay platform exhibited excellent selectivity and sensitivity with detection limit as low as 0.78 aM.

متن کامل

Frequency-shift vs phase-shift characterization of in-liquid quartz crystal microbalance applications.

The improvement of sensitivity in quartz crystal microbalance (QCM) applications has been addressed in the last decades by increasing the sensor fundamental frequency, following the increment of the frequency/mass sensitivity with the square of frequency predicted by Sauerbrey. However, this sensitivity improvement has not been completely transferred in terms of resolution. The decrease of freq...

متن کامل

Practical Strategies for Stable Operation of HFF-QCM in Continuous Air Flow

Currently there are a few fields of application using quartz crystal microbalances (QCM). Because of environmental conditions and insufficient resolution of the microbalance, chemical sensing of volatile organic compounds in an open system was as yet not possible. In this study we present strategies on how to use 195 MHz fundamental quartz resonators for a mobile sensor platform to detect airbo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014