Matrix-assisted laser desorption mass spectrometry of biotransformation products of dynorphin a in vitro.

نویسندگان

  • J Z Chou
  • M J Kreek
  • B T Chait
چکیده

The utility of matrix-assisted laser desorption mass spectrometry for characterizing products of in vitro processing of synthetic dynorphin A (Dyn A) peptides in biologic matrices is described. A series of laser desorption matrices were tested for their response to Dyn A (1-6), Dyn A (1-7), Dyn A (1-8), Dyn A (1-9), Dyn A (1-l0), Dyn A (1-13), Dyn A (2-17), and Dyn A (1-17). α-Cyano-4-hydroxycinnamic acid was chosen as a suitable matrix for subsequent studies. Mass spectra of dynorphin peptides indicated a good signal-to-noise response down to (1) 10 fmole of Dyn A (1-10) amide standard in aqueous acidic solution and (2) a concentration of 10(-7) M for seven dynorphin peptides spiked into human plasma. Two examples of the mass spectrometric analysis of the products of in vitro processing are presented: Dyn A (1-13) and Dyn A (1-17) in human blood. The presence and identity of processed peptides can be simply inferred from the molecular masses provided by the mass spectrometric measurement without extensive sample purification. A comparison of matrixassisted laser desorption mass spectrometry is made with high-performance liquid chromatography.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dynorphin A(1-17) biotransformation in striatum of freely moving rats using microdialysis and matrix-assisted laser desorption/ionization mass spectrometry.

The biotransformation of the opioid peptide dynorphin A(1-17) was investigated in striatum of freely moving Fischer rats, by direct infusion of this peptide, followed by recovery of the resulting biotransformation products via microdialysis and identification using matrix-assisted laser desorption/ionization mass spectrometry. The observed peptides are consistent with enzymatic cleavage at the ...

متن کامل

Dynorphin A (1-8) analog, E-2078, is stable in human and rhesus monkey blood.

E-2078 is a dynorphin A (1-8) analog, [N-methyl-Tyr1, N-methyl-Arg7-D-Leu8] Dyn A (1-8) ethylamide. Its biochemical stability against enzymatic degradation in vitro in human and rhesus monkey blood, and in vivo in rhesus monkey blood was studied using matrix-assisted laser desorption/ionization mass spectrometry. In vitro studies were carried out in freshly drawn human and rhesus monkey blood, ...

متن کامل

Dynorphin A (1-8) analog, E-2078, crosses the blood-brain barrier in rhesus monkeys.

E-2078 is a dynorphin A (1-8) analog, [N-methyl-Tyr1, N-methyl-Arg7-D-Leu8] dynorphin A (1-8) ethylamide. Its ability to cross the blood-brain barrier was examined in rhesus monkeys using matrix-assisted laser desorption/ionization mass spectrometry. In vivo studies were carried out by i.v. injecting E-2078, 10 mg/kg, a dose that had been found to be antinociceptive, to rhesus monkeys. Blood an...

متن کامل

l-DOPA-induced Dyskinesia is Associated with Regional Increase of Striatal Dynorphin Peptides as Elucidated by Imaging Mass Spectrometry*

Opioid peptides are involved in various pathophysiological processes, including algesia, epilepsy, and drug dependence. A strong association between L-DOPA-induced dyskinesia (LID) and elevated prodynorphin mRNA levels has been established in both patients and in animal models of Parkinson's disease, but to date the endogenous prodynorphin peptide products have not been determined. Here, matrix...

متن کامل

L-DOPA-induced Dyskinesia is Associated with Regional Increase of Striatal Dynorphin Peptides as Elucidated by Imaging Mass Spectrometry*□S

Opioid peptides are involved in various pathophysiological processes, including algesia, epilepsy, and drug dependence. A strong association between L-DOPA-induced dyskinesia (LID) and elevated prodynorphin mRNA levels has been established in both patients and in animal models of Parkinson’s disease, but to date the endogenous prodynorphin peptide products have not been determined. Here, matrix...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American Society for Mass Spectrometry

دوره 5 1  شماره 

صفحات  -

تاریخ انتشار 1994