Doppler echocardiographic criteria in patency assessment of composite grafts from left internal thoracic artery.

نویسندگان

  • Maria Claudia A Leitão
  • José Glauco Lobo Filho
  • Tiago Magalhães Freire
  • Marília Leitão Montenegro
  • Francisco Vagnaldo Fechine Jamacuru
  • Eduardo Rebouças de Carvalho
  • Amanda Ximenes Couto Bem
  • Heraldo Guedis Lobo Filho
  • Manuel Odorico de Moraes Filho
چکیده

OBJECTIVES The purpose of our study was to establish, with an entirely noninvasive method, transthoracic Doppler echocardiography, criteria for patency of composite left internal thoracic artery grafts when placed on the left anterior descending artery and other branches of the left coronary system. METHODS The control group comprised 20 patients with single graft and 20 patients with composite graft; all forty having their patency confirmed by coronary angiogram (CA). In this control group, two Doppler echocardiographic variables, diastolic mean velocity-time and integral diastolic peak velocity to systolic peak velocity ratio were recorded. For each variable, established cut-off points were established, using the ROC (Receiver Operator Characteristic) curves, to identify criteria which could differentiate the composite grafts. Only patients with composite grafts were included in the 159-patients study group. The criteria established by the cut-off points in the control group were then applied to detect patency using a diastolic fraction of > 0.5 as the gold standard. The sensitivity, specificity, and positive and negative predictive values of these two criteria were determined. RESULTS In the control group, cut-off points of 0.71 and 0.09 m were established for the diastolic peak velocity/systolic peak velocity ratio and for diastolic mean velocity-time integral, respectively. In the study group phase, the sensitivity and negative predictive value of the diastolic peak velocity/systolic peak velocity > 0.71 criterion were 36% and 11%, respectively. Diastolic mean velocity-time integral > 0.09 m criterion, were 40% and 10.48%. The specificities and positive predictive values of each criterion were 100%. CONCLUSION Values reaching the criteria established for each variable indicate high probability of composite graft patency. Lower values have a large proportion of false negatives and are not conclusive as patency criteria.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Doppler echocardiographic flow pattern of the left internal thoracic artery following myocardial revascularization using a composite graft.

Doppler echocardiographic studies of left internal thoracic artery (LITA) grafts, pedicled to the anterior interventricular artery (AIA) became a significant non-invasive method to evaluate graft blood flow and patency at the end of the 90’s. A detailed comparison of blood flow from an in situ LITA and an implanted LITA graft reveals that the in situ LITA has a predominantly systolic flow patte...

متن کامل

Transthoracic Doppler echocardiography of the left internal mammary artery graft.

Assessment of the left internal mammary artery (LIMA) graft patency currently requires invasive investigation through coronary angiography. In the last years the successful application of noninvasive Doppler spectrum analysis has been reported for patency assessment of the LIMA graft after myocardial revascularization. Echocardiography is considered to be a sensitive noninvasive screening modal...

متن کامل

Changing flow pattern of the internal thoracic artery undergoing coronary bypass grafting: continuous-wave Doppler assessment.

Surgeons have limited ability to evaluate intraoperatively the patency of internal thoracic artery graft as a bypass for coronary artery revascularization. We used continuous-wave Doppler ultrasonography to study the velocity of the internal thoracic artery before harvesting and after grafting (scanning probe, 8 MHz). Systolic and diastolic frequency shift (in kilohertz) and systolic frequency/...

متن کامل

Assessment of internal mammary artery and saphenous vein graft patency and flow reserve using transthoracic Doppler echocardiography.

OBJECTIVE To investigate transthoracic Doppler echocardiography in the identification of coronary artery bypass graft (CABG) flow for assessing graft patency. DESIGN The initial study group comprised 45 consecutive patients with previous CABG undergoing elective cardiac catheterisation for recurrent ischaemia. The Doppler variables best correlated with angiographic graft patency were then tes...

متن کامل

Intraoperative flow measurements in gastroepiploic grafts using pulsed Doppler.

OBJECTIVE The patency of a pedicled right gastroepiploic artery (RGEA) graft can be compromised by intraoperative twists, kinks or spasms. Therefore, a systematic flow assessment was made in RGEA grafts and was compared with similar measurements made in other types of bypass conduits. METHODS Intraoperative pulsed Doppler flowmeter measurements obtained in a series of 556 consecutive patients...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Revista brasileira de cirurgia cardiovascular : orgao oficial da Sociedade Brasileira de Cirurgia Cardiovascular

دوره 28 2  شماره 

صفحات  -

تاریخ انتشار 2013