LITHIUM GADOLINIUM BORATE IN PLASTIC SCINTILLATOR AS AN ANTINEUTRINO DETECTION MATERIAL by
نویسندگان
چکیده
Public reporting burden for this collection of information is estimated to average 1 hour per response, including the time for reviewing instruction, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information. Send comments regarding this burden estimate or any other aspect of this collection of information, including suggestions for reducing this burden, to
منابع مشابه
Remote Monitoring of Reactors: The Watchman Project In 2001, Bernstein, West and Gupta [i] described a possible campaign to monitor nuclear fission reactions over large distances using arrays of Super-Kamiokande (Super-
In 2001, Bernstein, West and Gupta [i] described a possible campaign to monitor nuclear fission reactions over large distances using arrays of Super-Kamiokande (SuperK) type water Cherenkov detectors, modified to include neutron-capture elements such as gadolinium. This modification would allow sensitivity to reactor and other low energy antineutrinos through the inverse beta decay interaction....
متن کاملA Backscatter-Suppressed Beta Spectrometer for Neutron Decay Studies
We describe a beta electron spectrometer for use in an upcoming experiment that will measure the beta-antineutrino correlation coefficient (a coefficient) in neutron beta decay. Electron energy is measured by a thick plastic scintillator detector. A conical array of plastic scintillator veto detectors is used to suppress events where the electron backscattered. A Monte Carlo simulation of this ...
متن کاملCalculations of absorbed dose and energy dependent of small-scale dosimeters for photons beam therapy
In this study, the energy dependency for dosimeters of air ionization chambers, lithium fluoride, silicon and plastic scintillator has been studied using the MCNPX Monte Carlo simulation code and simulated for gamma energy in the range of radiotherapy energy. The simulation results show that the response of each of the dosimeters for gamma photon beams in the energy range of 0.2 to 20 MeV varie...
متن کاملInvestigating the capability of plastic scintillation detectors in design of a muon radiography system by Geant4 code
Imaging and identifying materials with high atomic numbers and densities, especially radioactive materials, is one of the issues that have been especially considered in recent years. Due to some limitations in conventional and old imaging techniques, finding an alternative method is very important. The cosmic muons with an infinite source are one of the sources that have been recently studied f...
متن کاملDevelopment of the Dual Scintillator Sheet and Phoswich Detector for Simultaneous Alpha- and Beta-rays Measurement
Thin sheet type of ZnS(Ag)/plastic dual scintillator for simultaneous counting of alphaand betaparticles using a organic and inorganic scintillator widely used in the radiation measurement was manufactured, which could be applicable in the contamination monitoring systems. Counting materials were manufactured by solidification of the scintillator solution which mixed scintillator, solvent, and ...
متن کامل