Direct rapid analysis of trace bioavailable soil macronutrients by chemometrics-assisted energy dispersive X-ray fluorescence and scattering spectrometry.
نویسندگان
چکیده
Precision agriculture depends on the knowledge and management of soil quality (SQ), which calls for affordable, simple and rapid but accurate analysis of bioavailable soil nutrients. Conventional SQ analysis methods are tedious and expensive. We demonstrate the utility of a new chemometrics-assisted energy dispersive X-ray fluorescence and scattering (EDXRFS) spectroscopy method we have developed for direct rapid analysis of trace 'bioavailable' macronutrients (i.e. C, N, Na, Mg, P) in soils. The method exploits, in addition to X-ray fluorescence, the scatter peaks detected from soil pellets to develop a model for SQ analysis. Spectra were acquired from soil samples held in a Teflon holder analyzed using (109)Cd isotope source EDXRF spectrometer for 200 s. Chemometric techniques namely principal component analysis (PCA), partial least squares (PLS) and artificial neural networks (ANNs) were utilized for pattern recognition based on fluorescence and Compton scatter peaks regions, and to develop multivariate quantitative calibration models based on Compton scatter peak respectively. SQ analyses were realized with high CMD (R(2)>0.9) and low SEP (0.01% for N and Na, 0.05% for C, 0.08% for Mg and 1.98 μg g(-1) for P). Comparison of predicted macronutrients with reference standards using a one-way ANOVA test showed no statistical difference at 95% confidence level. To the best of the authors' knowledge, this is the first time that an XRF method has demonstrated utility in trace analysis of macronutrients in soil or related matrices.
منابع مشابه
Total Reflection X-ray Fluorescence Spectrometry for Characterization of Nuclear Materials
Total reflection X-Ray Fluorescence (TXRF) is a comparatively new technique of material characterization and trace element analysis. It is an advanced variant of Energy Dispersive X-ray Fluorescence (EDXRF) and is based on the principle of total reflection of X-rays when these radiations fall on a flat smooth surface at a grazing angle less than the critical angle of the sample support. The cri...
متن کاملInternational Journal of Current Research in
Article Info The aim of this study is to investigate the contents of essential, macro and micro elements by the energy-dispersive X-ray fluorescence spectrometry (EDXRF) in different seaweeds (10 red algae, 5 green algae)from collected different regions of Visakhapatnam coast(India). Seaweeds from different estuarine stations were analyzed by X-ray fluorescence, providing results for the concen...
متن کاملDetermination of High Zn and Pb Concentrations in Polluted Soils Using Energy-Dispersive X-ray Fluorescence Spectrometry
A method of determination of high Zn and Pb concentrations by means of EDXRF (energy-dispersive X-ray fluorescence spectrometry) is presented. Zn and Pb concentration in soil samples from contaminated areas ranged within a limit of Zn: 800–2000ppm and Pb: 200–600ppm. Soil analysis was conducted directly after the samples had been dried and powdered, as well as in situ in polluted areas. Due to ...
متن کاملElemental Analysis of Different Radish (raphanus Sativus L.) Cultivars by Using Wavelength-dispersive X-ray Fluorescence Spectrometry (wdxrf)
KAYMAK, H. C., I. GUVENC and A. GUROL, 2010. Elemental analysis of different radish (Raphanus sativus L.) Cultivars by using wavelength-dispersive X-ray fluorescence spectrometry (WDXRF). Bulg. J. Agric. Sci., 16: 769-774 The aim of this work is to study the applicability of a quantitative WDXRF (Wavelength-Dispersive X-ray Fluorescence) method, for determination of minerals in radish specimens...
متن کاملSimultaneous determination of trace elements in serum by energy-dispersive x-ray fluorescence spectrometry.
Energy-dispersive x-ray fluorescence is applied in the analysis of human serum to determine the concentrations of several elements simultaneously with minimal manipulation of the sample. The analytical procedure has been developed with standard sera, and standardization, detection limits, and reproducibility have been established. A 50-microL sample of diluted serum, to which an internal standa...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Analytica chimica acta
دوره 729 شماره
صفحات -
تاریخ انتشار 2012