Sparse/Low Rank Constrained Reconstruction for Dynamic PET Imaging
نویسندگان
چکیده
In dynamic Positron Emission Tomography (PET), an estimate of the radio activity concentration is obtained from a series of frames of sinogram data taken at ranging in duration from 10 seconds to minutes under some criteria. So far, all the well-known reconstruction algorithms require known data statistical properties. It limits the speed of data acquisition, besides, it is unable to afford the separated information about the structure and the variation of shape and rate of metabolism which play a major role in improving the visualization of contrast for some requirement of the diagnosing in application. This paper presents a novel low rank-based activity map reconstruction scheme from emission sinograms of dynamic PET, termed as SLCR representing Sparse/Low Rank Constrained Reconstruction for Dynamic PET Imaging. In this method, the stationary background is formulated as a low rank component while variations between successive frames are abstracted to the sparse. The resulting nuclear norm and l1 norm related minimization problem can also be efficiently solved by many recently developed numerical methods. In this paper, the linearized alternating direction method is applied. The effectiveness of the proposed scheme is illustrated on three data sets.
منابع مشابه
Low-Rank Modeling of Local $k$-Space Neighborhoods (LORAKS) for Constrained MRI
Recent theoretical results on low-rank matrix reconstruction have inspired significant interest in low-rank modeling of MRI images. Existing approaches have focused on higher-dimensional scenarios with data available from multiple channels, timepoints, or image contrasts. The present work demonstrates that single-channel, single-contrast, single-timepoint k-space data can also be mapped to low-...
متن کاملBeyond Low Rank + Sparse: Multi-scale Low Rank Reconstruction for Dynamic Contrast Enhanced Imaging
PURPOSE: Dynamic Contrast Enhanced (DCE) MRI is a powerful method that can provide comprehensive information to characterize lesions. High temporal resolution is often desired for 3D DCE, but at the cost of lower spatial resolution. Low rank / partial separable methods offer an effective way of balancing this tradeoff by exploiting spatio-temporal correlations of dynamic images. However, existi...
متن کامل4D PET: Beyond conventional dynamic PET imaging
In this paper, we review novel techniques in the emerging field of spatiotemporal 4D PET imaging. We will discuss existing limitations in conventional dynamic PET imaging which involves independent reconstruction of dynamic PET datasets. Various approaches that seek to attempt some or all of these limitations are reviewed in this work, including techniques that util...
متن کاملLow-Rank and Sparse Decomposition Model for Accelerating Dynamic MRI Reconstruction
The reconstruction of dynamic magnetic resonance imaging (dMRI) from partially sampled k-space data has to deal with a trade-off between the spatial resolution and temporal resolution. In this paper, a low-rank and sparse decomposition model is introduced to resolve this issue, which is formulated as an inverse problem regularized by robust principal component analysis (RPCA). The inverse probl...
متن کاملAccelerated Cardiac Cine Using Locally Low Rank and Total Variation Constraints
INTRODUCTION: Simultaneously achieving high spatial and temporal resolution remains a challenge in 3D cardiac cine imaging. Constrained reconstruction promoting the low rank property of dynamic image matrices has been proposed for accelerated dynamic MRI [1,2]. Recently, locally low rank (LLR) constraint was proposed to exploit spatially-varied local rank-deficiency [3]. Moreover, the combinati...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 10 شماره
صفحات -