Laser thermal therapy: utility of interstitial fluence monitoring for locating optical sensors.

نویسندگان

  • W M Whelan
  • P Chun
  • L C Chin
  • M D Sherar
  • I A Vitkin
چکیده

Multipoint optical fluence measurements can potentially be used to detect coagulation-induced changes in optical propagation during interstitial laser thermal therapy. Estimating the dimensions of coagulation using on-line optical monitoring, which is applicable to treatments where the tip of the source fibre is not precharred, may be limited by the accuracy of the placement of optical sensors with respect to source fibres. A strategy has been developed to determine accurately the position of a four-sensor linear array, prior to treatment, using optical fluence data obtained from the sensors for low-power (< or = 0.5 W) irradiation. A minimum of four sensors in an array was required in order to develop a mathematical formulation for position determination that did not require tissue optical properties or laser power as input. Optical propagation was based on diffusion theory for homogeneous tissues in spherical geometry. Low input laser power is needed to ensure that there are no thermally induced changes in tissue optical properties not accounted for in the mathematical description. Experimental evaluation was performed in a tissue-equivalent liquid phantom using 0.5 W of 805 nm optical energy and a translatable isotropic optical sensor. For sensor locations with 2 mm spacing, placement accuracy of 0.67 mm was achieved. The accuracy improved to 0.13 mm as the sensor spacing increased to 5 mm.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Changes in relative light fluence measured during laser heating: implications for optical monitoring and modelling of interstitial laser photocoagulation.

Dynamic changes in internal light fluence were measured during interstitial laser heating of tissue phantoms and ex vivo bovine liver. In albumen phantoms, the results demonstrate an unexpected rise in optical power transmitted approximately I cm away from the source during laser exposure at low power (0.5-1 W), and a decrease at higher powers (1.5-2.5 W) due to coagulation and possibly charrin...

متن کامل

Characterization of measurement artefacts in fluoroptic temperature sensors: implications for laser thermal therapy at 810 nm.

BACKGROUND AND OBJECTIVES Fluoroptic sensors are used to measure interstitial temperatures but their utility for monitoring laser interstitial thermal therapy (LITT) is unclear because these sensors exhibit a measurement artefact when exposed to the near-infrared (NIR) treatment light. This study investigates the cause of the artefact to determine whether fluoroptic sensors can provide reliable...

متن کامل

Evaluation of Temperature Rise and Thermal Lesion Dimensions in Liver Laser Interstitial Thermotherapy

Introduction:  Laser  interstitial  thermotherapy  (LITT)  is  an  internal  ablation  therapy  method  consisting of a percutaneous or intraoperative insertion of laser fibers directly into the liver tumor with  maximum diameter of 5 cm. In this treatment method, there isn’t any general information about the  relationship  between  increasing  the  exposure  power,  coagulation  and  carboniza...

متن کامل

Induction of Localized Hyperthermia by Millisecond Laser Pulses in the Presence of Gold-Gold Sulphide Nanoparticles in a Phantom

Introduction Application of near-infrared absorbing nanostructures can induce hyperthermia, in addition to providing more efficient  photothermal effects. Gold-gold sulfide (GGS) is considered as one of these nanostructures. This study was performed on a tissue-equivalent optical-thermal phantom to determine the temperature profile in the presence and absence of GGS and millisecond pulses of a ...

متن کامل

Perturbative diffusion theory formalism for interpreting temporal light intensity changes during laser interstitial thermal therapy.

In an effort to understand dynamic optical changes during laser interstitial thermal therapy (LITT), we utilize the perturbative solution of the diffusion equation in heterogeneous media to formulate scattering weight functions for cylindrical line sources. The analysis explicitly shows how changes in detected interstitial light intensity are associated with the extent and location of the volum...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physics in medicine and biology

دوره 46 4  شماره 

صفحات  -

تاریخ انتشار 2001