The risk of adverse events associated with atropine administration during dobutamine stress echocardiography in cardiac transplant patients: a 28-year single-center experience.

نویسندگان

  • James Wang Ji
  • Siqin Ye
  • Jennifer Haythe
  • P Christian Schulze
  • Daichi Shimbo
چکیده

BACKGROUND Although dobutamine stress echocardiography (DSE) is performed in heart transplant patients, the safety profile of atropine administration in DSE in this setting is unclear. METHODS AND RESULTS We identified heart transplant patients who received atropine during DSE from January 1984 to August 2011 at our institution and compared them with a propensity-scored matched control group of heart transplant patients who underwent DSE without atropine. Adverse events were defined as significant arrhythmias (sinus arrest, Mobitz type II heart block, complete heart block, ventricular tachycardia, or ventricular fibrillation), hypotension requiring hospitalization, syncope or presyncope, myocardial infarction, and death. Forty-five heart transplant patients (median age 62 years, 82% male) received 0.2-1 mg atropine during DSE. Of these, 1 patient (2.2%) developed temporary complete heart block. No adverse events were identified in the control group of 154 patients who received dobutamine without atropine. CONCLUSIONS Our findings suggest that complete heart block can occur infrequently with the administration of atropine in heart transplant patients undergoing DSE. Therefore, patients should be appropriately monitored for these adverse events during and after DSE.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Coronary Artery Spasm During Dobutamine Stress Echocardiography: A Case Report

Dobutamine stress echocardiography (DSE) has been widely used as a diagnostic and prognostic modality in the management of stress. DSE is associated with limited complications and adverse effects on the health of patients. In this case report, we described a 42-year-old female patient with dobutamine-induced coronary artery spasm with history of exertional dyspnea, which had deteriorated recent...

متن کامل

Syncope caused by cardiac asystole during dobutamine stress echocardiography.

Syncope caused by cardiac asystole during dobutamine stress echocardiography occurred in a 60 year old woman presenting with chest pain and a non-diagnostic exercise test. Cardiac asystole was not associated with myocardial ischemia and was attributed to a powerful cardioinhibitory vagal reflex elicited by the stimulation by the drug of cardiac and aortic mechanoreceptors. Cardiac asystole was ...

متن کامل

Long-term prognostic value of dobutamine-atropine stress echocardiography in 1737 patients with known or suspected coronary artery disease: A single-center experience.

BACKGROUND The purpose of this study was to assess the long-term value of dobutamine-atropine stress echocardiography (DSE) for prediction of late cardiac events in patients with proven or suspected coronary artery disease. METHODS AND RESULTS Clinical data and DSE results were analyzed in 1734 consecutive patients undergoing DSE between 1989 and 1997. Seventy-four patients who underwent reva...

متن کامل

Safety and efficacy of early atropine injection for dobutamine stress cardiac magnetic resonance: a single center experience

Introduction Dobutamine is an effective pharmacologic stress agent commonly used in cardiac stress testing, but has several well documented adverse effects including serious arrhythmias and myocardial infarction. The most common dobutamine protocol is to infuse an increasing dose of 10 μg/kg followed by 20, 30, then 40 μg/kg until target HR is achieved. Atropine may be added after the 40 μg/kg ...

متن کامل

Adverse effect of increased left ventricular wall thickness on five year outcomes of patients with negative dobutamine stress

BACKGROUND To determine if patients without dobutamine induced left ventricular wall motion abnormalities (WMA) but an increased LV end-diastolic wall thickness (EDWT) exhibit a favorable cardiac prognosis. RESULTS Between 1999 and 2001, 175 patients underwent a dobutamine stress cardiovascular magnetic resonance (DCMR) procedure utilizing gradient-echo cines. Participants had a LV ejection f...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of cardiac failure

دوره 19 11  شماره 

صفحات  -

تاریخ انتشار 2013