Sensitive and selective trypsin detection using redox cycling in the presence of L-ascorbic acid.

نویسندگان

  • Seonhwa Park
  • Haesik Yang
چکیده

We report a simple, sensitive, and selective electrochemical method for trypsin detection that can cover a wide range of concentrations. The method is based on the proteolytic generation of an electroactive species (P) by trypsin followed by a signal-amplified electrochemical measurement of P using electrochemical-chemical (EC) or electrochemical-chemical-chemical (ECC) redox cycling. The detection is performed using bare indium-tin oxide (ITO) electrodes without washing steps. P is generated by the cleavage of an amide bond between P and oligopeptide (Gly-Pro-Arg) at the C-terminal of Gly-Pro-Arg-P. Four trypsin products including 4-amino-1-naphthol (AN) and their trypsin substrates are investigated to obtain a high signal-to-background ratio in ECC redox cycling. AN and its trypsin substrate produce the highest signal-to-background ratio. The detection limits obtained with ECC redox cycling involving AN (approximately 1 ng mL(-1) and 100 ng mL(-1) with an incubation period of 2 h and 30 min, respectively) in Tris buffer (pH 8.0) are lower than those obtained with EC redox cycling involving AN (approximately 5 ng mL(-1) and 200 ng mL(-1) with an incubation period of 2 h and 30 min, respectively). In trypsin detection using ECC redox cycling, the interference effects of electroactive species such as l-ascorbic acid and uric acid are not significant.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Selective Determination of Dopamine in the Presence of Ascorbic Acid and Uric Acid at Neutral pH Using a Silver Nanoparticles-modified Carbon Paste Electrode

Developing simple, sensitive and selective sensing systems for dopamine is important due to its biological significance. In this work, a silver nanoparticles-modified carbon paste electrode (AgNPs-CPE) has been constructed and used to detect of dopamine (DA) in the simultaneous presence of ascorbic acid (AA) and uric acid (UA) at neutral pH 7.0 by cyclic voltammetry. The modified electrode show...

متن کامل

Simultaneous Determination of Ascorbic Acid, Uric Acid and Tryptophan by Novel Carbon Nanotube Paste Electrode

In the present paper, electrochemical methods were used to investigate the behavior of ascorbic acid at a carbon paste electrode modified with 2,2'-((1E)-(1,2 phenylenebis(azanylylidene)) bis(methanylylidene))bis(benzene-1,4-diol) (PBD) and oxidized multiwall carbon nanotubes. The modified carbon paste electrode showed high electrocatalytic activity toward ascorbic acid; the current was enhance...

متن کامل

Simultaneous Determination of Ascorbic Acid, Uric Acid and Tryptophan by Novel Carbon Nanotube Paste Electrode

In the present paper, electrochemical methods were used to investigate the behavior of ascorbic acid at a carbon paste electrode modified with 2,2'-((1E)-(1,2 phenylenebis(azanylylidene)) bis(methanylylidene))bis(benzene-1,4-diol) (PBD) and oxidized multiwall carbon nanotubes. The modified carbon paste electrode showed high electrocatalytic activity toward ascorbic acid; the current was enhance...

متن کامل

Fabrication of Nano Poly Cresol Red over Glassy Carbon Electrode and its Application in Selective Determination of Uric acid in the Presence of Ascorbic Acid

A selective electrochemical method for the determination of uric acid was developed by using nano poly cresol red modified glassy carbon electrode. This new material has been characterized by Scanning Electron Microscopy, cyclic voltammetry and Differential pulse voltammetry. This modified electrode shows excellent electrocatalytic activity towards the oxidation of uric acid in the presence of ...

متن کامل

Sensitive Voltammetric Determination of Acetaminophen at Poly(4-vinyl pyridine)/Graphene Composite Modified Electrode

This study demonstrates the use of a selective and sensitive voltammetric sensor for determination of acetaminophen (AC). This was  performed by modifying a glassy carbon electrode with composite film of poly(4-vinylpyridine) and graphene sheet (P4VP/GR-GCE). The redox peak currents of AC increased significantly at P4VP/GR-GCE. The result was achieved by the synergistic effect of combined elect...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Analyst

دوره 139 16  شماره 

صفحات  -

تاریخ انتشار 2014