Segmentation of Extracellular Microelectrode Recordings with Equal Power
نویسندگان
چکیده
We describe a segmentation algorithm for extracellular microelectrode recordings identifying segments with equal power. The observed temporal correlation of the microelectrode data was accounted for by estimating the variance of the autocovariance of the segments. The iterative method of comparing segments and determining abrupt changes in the power was validated on synthetic signals and microelectrode recording data acquired at different neuronal structures along the stereotactic trajectory in patients with
منابع مشابه
Statistical Methods of Analysis and Visualization of Extracellular Microelectrode Recordings
Determining neuronal structures during stereotactic surgery in Parkinsons disease (PD) patients is a prerequisite for optimal placement of deep brain stimulation electrodes and/or neuronal ablation. This study describes statistical signal processing methods that automatically analyze microelectrode recordings and display a neurophysiological brainmap of the stereotactic trajectory. The sponta...
متن کاملComparison between intracellular and extracellular direct current recordings of sinus node activity for evaluation of sinoatrial conduction time.
For evaluation of sinoatrial conduction time in humans, study of extracellular direct current (DC) electrograms from the sinus node has been proposed. To validate this method, we compared transmembrane potentials from multiple sites (40 to 60, "mapping" of sinoatrial activation by microelectrode technique) and extracellular DC electrograms of the sinus node in 12 isolated rabbit atria. Sinoatri...
متن کاملProtective role of cyclosporine on the model simulated the rotational nodal arrhythmia (AVNRT) by using extracellular field potential recordings of isolated atrioventricular-node of rabbit
Introduction: Recent studies have shown acute cardioprotective effects of cyclosporine. The aim of the present study was to determine the protective role of cyclosporine on the model simulated the rotational nodal arrhythmia (AVNRT) by using extracellular field potential recordings of isolated atrioventricular-node (AV-node) of rabbit. Methods: This study was performed on isolated double-per...
متن کاملCortical signal recording using an economical microelectrode fabricated on printed circuit board
This work presents a simple, flexible and economical microwire array electrode for extracellular cortical recordings. The proposed procedure is relatively simple, even for a novice worker to implement in-house. These main steps include design and sculpturing PCB, straightening microwires, connecting PCB pattern, arraying and soldering microwires and packaging the microelectrode. A practiced res...
متن کاملOn-chip, multisite extracellular and intracellular recordings from primary cultured skeletal myotubes
In contrast to the extensive use of microelectrode array (MEA) technology in electrophysiological studies of cultured neurons and cardiac muscles, the vast field of skeletal muscle research has yet to adopt the technology. Here we demonstrate an empowering MEA technology for high quality, multisite, long-term electrophysiological recordings from cultured skeletal myotubes. Individual rat skelet...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2003