Continuous-flow serum albumin determination by reaction with picrate ions, with use of a flow-through picrate ion electrode.

نویسندگان

  • E P Diamandis
  • D S Papastathopoulos
  • T P Hadjiioannou
چکیده

An automated potentiometric method for serum albumin determination by use of the picrate/albumin reaction is described. A continuous-flow system and a specially designed flow-through picrate ion electrode were used in making the measurements. Various factors affecting the reaction, such as pH, picrate ion concentration, and reaction time, were studied. Peak height in millivolts and albumin concentration were linearly related in the range 10-70 g/L. Both within-run and day-to-day, the CV for the method was about 2%. Analytical recovery of albumin added to serum samples ranged from 97.0 to 110.3%, averaging 102.2%. Results compare favorably with those by the established bromcresol green method. The proposed method is suitable for routine use and for screening tests.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Automated development of a kinetic method for the continuous-flow determination of creatinine.

A "stopped-flow" method for the kinetic Jaffé determination of creatinine was developed, with the use of a computer-controlled continuous-flow system. Simplex optimization was used to find conditions of hydroxide and picrate giving maximum sensitivity for creatinine. We used a modified central composite experimental design to evaluate creatinine sensitivity and albumin, glucose, and acetone int...

متن کامل

Kinetic potentiometric determination of creatinine in serum with a picrate ion-selective membrane electrode.

We describe a new kinetic method for potentiometric determination of creatinine in serum, based on the creatinine--picrate reaction in alkaline medium (Jaffé reaction). The reaction is monitored with a picrate-selective electrode, and the increase in electrode potential during 270 s is measured and related directly to the creatinine concentration. Small cation-exchange columns are used to separ...

متن کامل

Rapid and precise coulometric determination and separation of redox inert ions based on electrolysis for ion transfer at the aqueous|organic solution interface.

Flow systems for precise and accurate coulometric determinations of ions that were developed on the basis of electrolytic ion transfer at the aqueous|organic solution (W|O) interface are reviewed. The electrolysis cell in the system is composed of a porous poly(tetrafluoroethylene) tube (1.0 mm inner diameter), a metal wire (0.8 mm diameter) inserted into the tube, O into which the tube is imme...

متن کامل

Lactulose interferes in the alkaline picrate assay for creatinine.

Errors of more than 10 mg/L in measured serum creatinine concentrations were encountered for an azotemic patient who was given lactulose orally. The magnitude of the apparent error fluctuated with the dose of lactulose. Additions of lactulose to serum produced a linear increase in the creatinine measured by each of two automated methods that involve use of the alkaline picrate (Jaffé) reaction....

متن کامل

Sensing of Iron Ions by Solid Phase Spectrophotometry

A new sensitive and selective spectrophotometric method for the determination of iron using a PVC membrane containing bathophenanthroline and dioctylphethalate as the solid phase extraction medium is investigated. Fe(II) in an aqueous sample solution is trapped on the membrane with an anion species, picrate ion and forms a complex with bathophenanthroline. The absorbance of the red-orange m...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 27 3  شماره 

صفحات  -

تاریخ انتشار 1981