Analysis and Identification of an Intraocular Pressure Waveform
نویسندگان
چکیده
Certain ocular diseases such as glaucoma cause an increase in the internal pressure of the eye, damaging nerves. An implantable pressure sensor would give patients the ability to monitor their own intraocular pressure and then consult a physician if necessary. One device to do this has been developed using a microscopic Fabry-Perot interferometer with the plates implanted between the intraocular membranes, and Raman spectroscopy measurements taken to determine the distance between the plates and thus the pressure in the eye. However the signal produced is difficult for a machine to recognize and link to the pressure environment of the sensor. To analyze the signals and convert their differences into numerical quantities, various signal processing techniques were investigated, such as using Fourier transforms, polynomial fit, and simple peak matching. A program combining these techniques to compare frequency shift across pressures and angles is currently being tested for consistency over samples at the same pressure.
منابع مشابه
ORA waveform-derived biomechanical parameters to distinguish normal from keratoconic eyes.
PURPOSE To evaluate the ability of the Ocular Response Analyzer (ORA; Reichert Ophthalmic Instruments, Buffalo, NY) to distinguish between normal and keratoconic eyes, by comparing pressure and waveform signal-derived parameters. METHODS This retrospective comparative case series study included 112 patients with normal corneas and 41 patients with bilateral keratoconic eyes. One eye from each...
متن کاملEvaluation of the diurnal intraocular pressure fluctuations and blood pressure under dehydration due to fasting
Introduction: This study aimed to investigate the diurnal intraocular pressure fluctuations under dehydration conditions and the relationship between the intraocular pressure fluctuations and blood pressure. Methods: The intraocular pressures (IOP), body weights, as well as systolic and diastolic blood pressures (SBP, DBP) of 36 fasting healthy volunteers were recorded at 8:00 a.m. and 5:00 p.m...
متن کاملA System for Continuous Estimating and Monitoring Cardiac Output via Arterial Waveform Analysis
Background: Cardiac output (CO) is the total volume of blood pumped by the heart per minute and is a function of heart rate and stroke volume. CO is one of the most important parameters for monitoring cardiac function, estimating global oxygen delivery and understanding the causes of high blood pressure. Hence, measuring CO has always been a matter of interest to researchers and clinicians. Sev...
متن کاملEvaluation of various factors relating to intraocular pressure and C/D ratio
Introduction: Intraocular pressure (IOP) is determined by three factors: the rate of aqueous humor production by the ciliary’s body, the resistances to aqueous out flow across the trabecular meshwork and the level of episcleral vessel pressure. IOP varies with a number of factors, including: age, sex, race, systemic disease and diurnal variation. The purpose of this study is measurement of IO...
متن کاملEffects of concomitant administration of latanoprost and pilocarpine on the intraocular pressure of experimentally glaucomatous rabbits
The purpose of this study was to evaluate the effects of a combination of latanoprost and pilocarpine onthe intraocular pressure in experimentally glaucomatous rabbits. Ocular hypertension was induced in 11conscious rabbits by the oral administration of tap water (70 mL/kg) via an orogastric tube. The study wasconducted in three therapeutic groups to test the effects of latanoprost (group L), p...
متن کامل