Physiological noise compensation in gradient-echo myelin water imaging

نویسندگان

  • Yoonho Nam
  • Dong-Hyun Kim
  • Jongho Lee
چکیده

In MRI, physiological noise which originates from cardiac and respiratory functions can induce substantial errors in detecting small signals in the brain. In this work, we explored the effects of the physiological noise and their compensation methods in gradient-echo myelin water imaging (GRE-MWI). To reduce the cardiac function induced inflow noise, flow saturation RF pulses were applied to the inferior portion of the head, saturating inflow blood signals. For the respiratory function induced B0 fluctuation compensation, a navigator echo was acquired, and respiration induced phase errors were corrected during reconstruction. After the compensations, the resulting myelin water images show substantially improved image quality and reproducibility. These improvements confirm the importance and usefulness of the physiological noise compensations in GRE-MWI.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

In Vivo Myelin Water Imaging Using 3d Multi-gradient-echo Pulse Sequences

Introduction. Quantitative imaging of the myelin water fraction (MWF) is able to show demyelinating processes and therefore provides insight into the pathology of white matter (WM) diseases such as multiple sclerosis. So far, mapping of the MWF most often was performed using single-slice multi-echo spin-echo sequences (1). Lately, a different approach, using multi-gradient-echo pulse sequences,...

متن کامل

Echo time optimization for linear combination myelin imaging.

A 3-echo linear combination myelin imaging method is presented. The echo times and weights are chosen such that the signal-to-noise ratio (SNR) of myelin-water is maximized, and signals from other white matter components are sufficiently suppressed. Interfering tissue water and cerebrospinal fluid (CSF) signals are much stronger than myelin due to their longer T2 and abundance. By carefully opt...

متن کامل

Ultrashort Echo Time (UTE) MR Lung Imaging with Respiratory Motion Compensation

Introduction: Conventional gradient-echo based magnetic resonance imaging of lung parenchyma suffers from poor signal-to-noise ratios due to low proton density and short T2* caused by susceptibility gradients between airways and tissue. In addition, respiratory and cardiac motions seriously degrade the achievable image quality. Ultra-short echo time (UTE) MRI has recently gained renewed attenti...

متن کامل

Spectral Adiabatic Inversion Recovery (SPAIR) MR imaging of the Abdomen

Magnetic resonance imaging (MRI) has become a major imaging tool for the depiction and characterization of abdominal disease. Standard abdominal MRI protocols encompass different forms of T1-weighted (T1w) and T2-weighted (T2w) data acquisition. These sequences can be collected in less than 20 seconds, which typically is within the patients’ ability to suspend respiration. Hence, artifacts due ...

متن کامل

Improved estimation of myelin water fraction using complex model fitting

In gradient echo (GRE) imaging, three compartment water modeling (myelin water, axonal water and extracellular water) in white matter has been demonstrated to show different frequency shifts that depend on the relative orientation of fibers and the B0 field. This finding suggests that in GRE-based myelin water imaging, a signal model may need to incorporate frequency offset terms and become a c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • NeuroImage

دوره 120  شماره 

صفحات  -

تاریخ انتشار 2015